Add system like this, Remove system, Clear password for system – HP Neoview Release 2.4 Software User Manual

Page 16: Test system

Advertising
background image

Add System Like This

To add a system like the selected system’s current settings:

Select the system definition you want to duplicate in the Systems Tool window.

Click [Add Like]. This opens the Add Like System window.

In the Add Like System window:
— A new name has to be specified in the field “Your name for the system.”
— Validate the system information specified for the selected system. The title bar displays

the system whose settings are being used as a template for the new system.

— Select [OK]. You can also select [Test] to test the new system.

Remove System

To remove a selected system:

Select the system you want to remove in the Systems Tool window.

Click [Remove] in the Systems Tool window. This opens a Remove Confirmation window.

In the Remove Confirmation window:
— Click [Yes] to remove the system definition, and close the Remove Confirmation

window.

— Click [No] to retain the system definition and close the Remove Confirmation window.

Clear Password for System

To clear a password for a selected system:

Select the system that you want to clear the password for in the Systems Tool window.

Click [Clear Password]. This opens a Clear Password Confirmation window.

In the Clear Password Confirmation window:
— Click [Yes] to clear the password for the selected system, and close the Clear Password

Confirmation window.

— Click [No] to retain the password for the selected system, and close the Clear Password

Confirmation window.

Once the password is cleared, the system is moved under “My Other Systems.”

Test System

To test the validity of a selected system:

Click [Test]. This action will:
— Cause an attempt to make a connection to the Neoview system specified in the selected

system definition.

— Return the validating result in the Connection Test Result window that indicates the

following:

Test succeeded

– the settings have been tested and the system is added to the

My Active Systems folder.

Test failed

– the settings have been tested and the test failed. If the test failed,

the reason for the failure in also provided in the Connection Test Result window.
The system is added to the My Other Systems folder.

Password not specified

– the password has been specified. If the password

is empty, you must have clicked in this field to explicitly set an empty password.
The system is added to the My Other Systems folder.

Not tested

– the entry is possibly empty and has not been tested. The system is

added to the My Other Systems folder.

16

The Systems Tool

Advertising