Bladesystem switches – HP Storage Essentials Enterprise Edition Software User Manual

Page 75

Advertising
background image

HP Storage Essentials SRM 6.0 User Guide

37

HP SIM does not allow blank passwords. Since these switches do not use a password, enter

anything for the password.

The management server does not support provisioning for Sun StorEdge, QLogic, and HP

M-Series switches. Only the active zone set and its zone members are reported.

To manage a fabric of Sun StorEdge, QLogic, or HP M-Series switches, every switch in the fabric

must be included in the discovery list. If a switch is not included in the discovery list, it may show

up as a generic host system.

No ports are reported for uninstalled blades or GBICs.

The default SNMP trap listener port for switches is 162. To change this port, see ”

Changing the

SNMP Trap Listener Port and Community String for Switches Discovered with SNMP

” on

page 46.

To receive events from Sun StorEdge, QLogic, and HP M-Series switches, verify that the SNMP

trap community string is set to match the community string defined in the HP Storage Essentials

custom properties (the default is public), and make sure the SNMP traps are configured to be

sent to the management server. For more information, see

Changing the SNMP Trap Listener

Port and Community String for Switches Discovered with SNMP

” on page 46

Note the following when discovering these switches with SMI-S:

Before you can discover these switches with SMI-S, you must download and install the cimserver

software. For more information, see the document QLogic SANbox 52xx and 56xx Switches or

HP StorageWorks M-Series for p-Class BladeSystems at:

http://www.hp.com/go/hpsim/providers

.

You must perform Discovery Data Collection to obtain all available information from QLogic

SMI-S switches—otherwise, attributes such as vendor, fabric, and port information will be

missing for the QLogic SMI-S switches.

NOTE:

You may see an error replicating the switch fabric name for QLogic-based switches.

This error can be ignored.

Discovery Information for Sun StorEdge, QLogic and HP StorageWorks M-Series for

p-Class BladeSystem Switches

To discover Sun StorEdge, QLogic and HP StorageWorks M-Series for p-Class BladeSystem Switches

switches, enter the following information in HP SIM:

IMPORTANT:

Provide the SNMP credentials in the WBEM settings section on the System Protocol

Settings page (Options > Protocol Settings > System Protocol Settings). Only the WBEM default

credentials are passed from HP SIM to HP Storage Essentials. Any default credential information you

set up in regards to SNMP is not passed from HP SIM to HP Storage Essentials.

System name or primary IP address of the switch you want to discover.

Do one of the following:
• For switches with SNMP connections, provide the user name for the switch. This is the public

community SNMP string for the switch.

Advertising
This manual is related to the following products: