HP Insight Management Agents User Manual

Page 66

Advertising
background image

1 Port Ultra320 SCSI Module - A 1 Port Ultra320 SCSI I/O Module is installed.

Unknown - The Storage Agents cannot determine the IO module type for this storage
system.

RSO Status displays the status of the Recovery Server Option. Two servers are connected to
the storage system so that when one fails the other server takes control of the storage system.
The following values are possible:

OK - The recovery server option is installed and the other server is working correctly.

Secondary Running - Auto - The recovery server option is installed, but the secondary
(standby) server is running in place of the primary server. The secondary server assumed
control automatically.

Secondary Running - User - The recovery server option is installed, but the secondary
(standby) server is running in place of the primary server. The secondary server assumed
control via manual intervention.

Link Down - The recovery server option is installed, but the communications link to the
secondary (standby) server is down.

No Secondary - The recovery server option is installed, but the communications link to
the secondary (standby) server has never been established.

Disabled - The recovery server option is installed, but it has been disabled by software.
This is done to temporarily prevent the secondary server from taking over when the primary
server is brought down. This is used to perform maintenance and other tasks on the
primary server.

Not Configured - The recovery server option is supported, but is not configured on this
storage system.

Not Supported - The recovery server option is not supported for this storage system.

Daemon Down - OK - The recovery server option is installed, but the RSO operating system
daemon is not running. The last RSO status was OK.

Daemon Down - Link Down - The recovery server option is installed, but the RSO operating
system daemon is not running. The last RSO status was Link Down.

Daemon Down - No Secondary - The recovery server option is installed, but the RSO
operating system daemon is not running. The last RSO status was No Secondary.

Daemon Down - Disabled - The recovery server option is installed, but the RSO operating
system daemon is not running. The last RSO status was Disabled.

EV Timeout Error - The recovery server option environment variable, that contains the
status, cannot be accessed. The attempted access timed out.

Unknown - The Storage Agents cannot determine the recovery server option status for this
storage system.

Preferred Path Mode displays the storage system active/active preferred path mode. The
following values are possible:

Not Active/Active - The storage system is not configured as active/active.

Automatic - The storage system automatically selects the preferred path for each logical
drive based on host I/O patterns.

66

Agent information