SL500 (M852x) Tape Library Installation and User’s Guide 541531-002

6 -1

6

Configuring the M8521 Tape Library
for the Integrity NonStop NS-Series
Server

The section covers:

Supported Connection

You can attach the M8521 tape library (control path and data path) to a Fibre Channel
ServerNet adapter (FCSA) on an Integrity NonStop NS-series server.

Adding the Control Path and Data Path

To add the control path, issue this SCFcommand:

SCF> ADD SCSI $device, SENDTO STORAGE, PRIMARYLOCATION
(group, module, slot), PRIMARYSAC sac-id, LUN lun-id,
PRIMARYPORT 64-bit-portname

Example:

SCF> ADD SCSI $M8521, SENDTO STORAGE, PRIMARYLOCATION
(110,2,2), PRIMARYSAC 2, LUN 0, PRIMARYPORT 1234567891234567

Supported Connection

6-1

Adding the Control Path and Data Path

6-1

Note. The control path is used to control the robot, and the data path is used to control the
tape drive or drives.

Note. To obtain the portname numbers for your control path and data path, contact a service
representative from STK. The portname numbers used in this section are examples only.