HP NonStop Time Synchronization User’s Guide

Page 68 of 81

Effect. The response is discarded and the update or report operation is canceled.

Recovery. Not necessary; TimeSync will automatically retry the update using the next
configured time source.

1013

1013: Could not proceed with operation due to time source error; time
source source
, error info: description

TimeSync could not adjust the local system clock or complete a report operation because
the response received from the configured time source was invalid. Note that this
message can occur even if the ReportOnly option is enabled, since TimeSync still needs to
obtain a reference time in order to calculate the clock difference between systems.

source

is the name/address of the time source from which the response was received.

description

is the specific error that occurred; for example, the response was received outside the
configured window, the time source time was invalid, etc.

Cause. The time source did not respond quickly enough, or the supplied reference time
was invalid.

Effect. The response is discarded and the update or report operation is canceled.

Recovery. Not necessary; TimeSync will automatically retry the update using the next
configured time source.

1014

1014: No time sources defined; action could not be completed

TimeSync, while running with MultiSource enabled, could not adjust the local system time
or complete a report operation because no time sources were defined. Note that this
message can occur even if the ReportOnly option is enabled, since TimeSync still needs to
obtain a reference time in order to calculate the clock difference between systems.

Cause. No time sources were defined when TimeSync attempted to initiate an update or
report operation

Effect. The update or report operation is canceled.