HP Brocade 4Gb SAN Switch for HP BladeSystem c-Class User Manual

Page 30

Advertising
background image

6.

Configure the terminal application as follows:

In a Windows environment, type:
• Bits per second — 9600
• Databits — 8
• Parity — None
• Stop bits — 1
• Flow control — None
In a UNIX environment, type: tip /dev/ttyb –9600

7.

Log into the OA.

8.

Press Enter to display the switch console.

9.

Identify the interconnect bay number where the switch is installed. At the OA

command line, type:

connect interconnect

x

Where x is the interconnect bay slot where the switch is installed.
a. User: admin
b. Password: password

NOTE:

Type entries as shown, as commands are case sensitive.

10.

Or, follow the onscreen prompts to change your password now.

11.

The OA will then connect its serial line to the Switch in the specified interconnect

bay. A prompt displays indicating that the escape character for returning to the OA

is Ctrl __ (underscore).

12.

At the command line, type: ipaddrset.

13.

Enter the remaining IP addressing information, as prompted.

14.

Optionally, enter ipaddrshow at the command prompt to verify that the IP address

is set correctly.

15.

Record the IP addressing information and store in a safe place.

16.

Type Exit and press Enter to log out of the serial console.

17.

Disconnect the serial cable. For additional assistance with operating the Onboard

Administrator CLI, refer to the Onboard Administrator Command Line Interface user

guide for your specific enclosure, available at

http://www.hp.com

.