HP Smart Array P800 Controller User Manual

Page 22

Advertising
background image

Upgrading or replacing controller options 22

If the battery case is mounted on the inner wall of the server chassis:

1.

Back up all data.

2.

Close all applications.

3.

Power down the server.

4.

Remove the server from the enclosure.

5.

Remove the server access panel.

6.

Remove the battery case from the chassis wall.

7.

Disconnect the cable from the battery.

8.

Remove the battery from the battery case.

9.

Install the replacement battery in the battery case.

10.

Connect the battery cable to the replacement battery.

11.

Mount the battery case on the chassis wall.

12.

Close the server access panel.

13.

Reinstall the server in the enclosure.

After installing a battery pack, you might see a POST message during reboot indicating that the array

accelerator (cache) is temporarily disabled. This behavior is normal because the new battery pack is likely
to have a low charge. You do not need to take any action because the recharge process begins

automatically when the battery pack is installed. The controller operates properly while the battery pack is

recharging, although the performance advantage of the array accelerator is absent. When the battery

pack has been charged to a predetermined level, the array accelerator is automatically enabled.
If the battery case is located in a hard drive slot:

1.

Back up all data.

2.

Close all applications.

3.

Power down the server.

4.

Remove the server from the enclosure.

5.

Remove the server access panel.

6.

Remove the battery case from the hard drive slot.

7.

Disconnect the battery cable.

8.

Invert the battery case.