join the VC Domain Group if it has any features enabled beyond the features supported by the
group firmware mode.

Table 4

illustrates how the group firmware mode is determined based on the versions of VC firmware

installed on the VC Domains in the VC Domain Group.

Table 4 Determining group firmware mode

Group firmware
mode

Domain D

Domain C

Domain B

Domain A

VC Domain
Group name

3.15

3.60

3.30

3.30

3.18

GroupOne

3.3x

3.7x

3.60

3.5x

3.30

GroupTwo

GroupOne contains three domains running 3.18, 3.30, and 3.60 VC firmware. The group firmware
mode is 3.15 because of the 3.18 VC Domain in the VC Domain Group.

GroupTwo contains three VC Domains running 3.30, 3.5x, 3.60, and 3.7x. The group firmware
mode is 3.3x because 3.30 is the lowest version in the group.

The group firmware mode also is a factor when creating a VC Domain Group based on a VC
Domain running a newer version of VC firmware than what is fully supported by the version of
VCEM managing the VC Domain Group. In this case, VCEM automatically sets the group firmware
mode when creating the VC Domain Group. VCEM sets the group firmware mode to the highest
firmware version that is fully supported by the version of VCEM being used to create the VC Domain
Group.

Table 5

shows the group firmware mode that will be set by recent versions of VCEM when the VC

Domain Group is created using a more recent version of VC firmware.

Table 5 Group firmware mode with recent versions of VC firmware

Resulting group firmware mode

Later firmware versions

VCEM version

3.15

3.3x, 3.5x, 3.6x

6.3

3.3x

3.5x, 3.6x, 3.7x

6.3u1

3.3x

3.5x, 3.6x, 3.7x

7.0

3.5x

3.7x

7.1

3.7x

4.0x

7.1.1

Creating a VC Domain Group based on a VC Domain running a newer version of VC firmware
requires that no features are enabled in the VC Domain that are beyond those supported by the
version of VCEM managing the VC Domain Group. For example, attempting to create a VC Domain
Group with VCEM 6.3 based on a domain with 3.30 installed and enhanced VLAN capacity
enabled will not succeed.

Preparing for a VCEM installation

IMPORTANT:

Starting with Insight Management 7.0, you must run VCEM on a 64-bit operating

system.

If you are upgrading your CMS and have VCEM 6.2 to 7.0 running on a 64-bit operating system,
you can directly update installations with the HP Insight Management DVD.

Figure 6 (page 20)

shows the 32-bit to 64-bit operating system update path.

Preparing for a VCEM installation

19