Storage System Startup

38

Enterprise Virtual Array 3000 User Guide

Storage System Connections

Figure 6

shows a typical Enterprise Virtual Array 3000 SAN topology:

The HSV controllers connect via ports FP1 and FP2 to two Fibre Channel
fabrics. The hosts that will access the storage system are connected to the
same fabrics. Note that FP1 on each controller is connected to a different
fabric to balance the I/O load.

Command View EVA, which runs on the storage management appliance, also
connects to both fabrics.

The controllers connect through two FC loops to the drive enclosures. The
loop pair consists of two independent loops, each capable of managing all the
disks should one loop fail.

Figure 6: Enterprise Virtual Array 3000 system connections

Browser

Host X

FCA

Management

Appliance

Command

View EVA

CXO8055B

Controller

A

FCA

FCA

FCA

Host Z

Browser

Non-Host

FP1

FP2

Loop
Pair 1

Loop
Pair 1

Controller

B

FP1

FP2

Network Interconnection

Drive Enclosures

FP = Fibre (Host) Port
FCA = Fibre Channel Adapter

Cache

Mirror Port

B

A

B

A

Fabric 1

Fabric 2