Command line 32

Examples

->show firmware
Displays a summary listing of all firmware

->show firmware *
Displays a detailed listing of all firmware

To update firmware, use the HP BladeSystem c-Class Virtual Connect Support Utility. For more information

on installing the firmware, see the HP BladeSystem c-Class Virtual Connect Support Utility documentation
on the HP website (

http://www.hp.com/go/bladesystem/documentation

).

igmp

Manage Ethernet IGMP Snooping settings.
Supported actions: help, set, show

Item

Description

set igmp

Modify Ethernet IGMP Snooping settings.

Syntax

set igmp [Enabled=<true|false>] [Timeout=<interval>]

Properties

Enabled

(optional)

Enables or disables IGMP Snooping. Valid values include "true" and "false".

Timeout

(optional)

The idle timeout interval (in seconds) for IGMP Snooping. Valid values include
integers from 1-3600. The default IGMP idle timeout is 260 seconds.

Examples

->set igmp Enabled=true
Enables IGMP Snooping

->set igmp Enabled=true Timeout=30
Enables IGMP Snooping and sets the idle timeout

Item

Description

show igmp

Display Ethernet IGMP Snooping settings.

Syntax

show igmp

Example

->show igmp
Displays IGMP Snooping settings

interconnect

Manage I/O interconnect modules.
Supported actions: help, remove, show

Item

Description

remove interconnect

Remove an interconnect module from the domain. Normally this command is
used if a module has been physically removed from the enclosure. To be

removed, the module must not be currently in use by any element in the
domain.