Table 26 Application modules—Error log messages (continued)

Description

No.

Log message

ID

Unable to create an object for
initiator object; exceeded the
maximum number of initiators

117

QLBA_CreateInitiatorObject: Too many initiators

41077

Process control block status
indicates that a PCI error occurred
during a target operation

136

QLBA_DisplayTargetOperationStatus: PCI Error, Status
0x%.2x

41096

Process control block status
indicates that a DMA error

146

QLBA_DisplayInitiatorOperationStatus: DMA Error, Status
0x%.2x

41106

occurred during an initiator
operation

Process control block status
indicates that a transport error

147

QLBA_DisplayInitiatorOperationStatus: Transport Error, Status
0x%.2x

41107

(protocol) occurred during an
initiator operation

Process control block status
indicates that a data overrun error

151

QLBA_DisplayInitiatorOperationStatus: Data Overrun, Status
0x%.2x

41111

occurred during an initiator
operation

iSCSI Login failed between receipt
of PDU and request for the data
segment.

274

QLIS_LoginPduContinue: Operation failed. Initiator 0x%x,
TPB status 0x%x

41234

iSCSI Login failed due to
unsupported version number in
received login PDU.

278

QLKV_ValidateLoginTransitCsgNsgVersion failed (status
0x%x)

41238

iSCSI Login PDU contains invalid
initiator name. The format and

297

QLIS_LoginPduContinue: Invalid initiator name. Initiator:

41257

character set used to form the
initiator name is invalid.

iSCSI target Login was attempted
to a portal (iSCSI1 or iSCSI2) on
which the target is not presented.

305

QLIS_LoginPduContinue: Target not configured for Portal

41265

iSCSI Login PDU received for a
target with a target name unknown
to the router.

307

QLIS_LoginPduContinue: Target not found. Target name:

41267

iSCSI Login PDU received without
a target name for a normal
session.

308

iSCSI Login PDU received without a target name for a normal
session.

41268

iSCSI Login PDU received without
an initiator name key or value.

310

iSCSI Login PDU received without an initiator name key/value
not provided.

41270

iSCSI Login PDU received with an
incorrect initiator task tag for a

312

QLIS_LoginPduContinue: CONN_STATE_IN_LOGIN,
Unknown InitTaskTag

41272

session which is partially logged
in. This would occur if a login PDU
other than the initial login PDU
used an initiator task tag that was
different than the initiator task tag
provided in the initial login PDU.

iSCSI Login PDU was received with
a TSIH out of range. This would

323

QLIS_LoginPduContinue: TSIH 0x%x out of range

41283

occur if the iSCSI initiator
attempting the login failed to used
the TSIH value provided in the

120 Log data