HP Brocade 4Gb SAN Switch for HP BladeSystem p-Class User Manual

Page 95

Advertising
background image

Fabric OS 5.0.0 procedures user guide

95

3.

Issue the

chassisconfig

command to change the configuration from the default (one domain) to

two domains. This command reboots the system.

chassisconfig 2

During the conversion, you are prompted to save the configuration of sw0. Follow the prompts to save

the configuration file.

4.

After the system reboots, log in again as admin to each logical switch.

5.

Using the configuration file saved in

step 3

as a guide, manually reconfigure sw0 and sw1.

Do not configure zoning parameters; these are propagated automatically when you merge the

director into the fabric.

6.

If the fabric is in secure mode, perform the following steps; otherwise, proceed to

step 7

.

a. Optionally, to configure sw0 and sw1 in one operation, connect them with an ISL link to form a

temporary fabric.

b. If you want sw0 and sw1 to be fabric configuration servers, update the overall fabric’s FCS policy

to include them. If not, skip this step.

c. On sw0, enable security mode and use the

secmodeenable

command to create an FCS list that

matches your overall fabric’s FCS policy.

d. Reset the version stamp on sw0.
e. If you connected sw0 and sw1 in

step 6a

and you do not want them connected, disconnect the ISL

link between them. If you did not connect them, repeat

step 6b

through

step 6d

on sw1.

7.

If you physically disconnected the switch in

step 2

, reconnect it to the fabric.

If you used the

portcfgpersistentdisable

command in

step 2

, use the

portcfgpersistentenable

command to persistently enable all ports that connect the switch to

other switches in the fabric.

8.

Use the

fabricshow

command to verify that sw0 and sw1 have been merged with the fabric.

9.

Use the

configshow

command to verify that zoning parameters were propagated.

Combining Core Switch 2/64 and SAN Director 2/128 cards

in one chassis

You can preserve your investment in legacy equipment by combining Core Switch 2/64 cards and SAN

Director 2/128 cards in one chassis.

The following procedure assumes that:

The Core Switch 2/64 has one logical switch (sw0, slots 1 through 4) populated with port cards. (You

can perform the same procedure on sw1 slots 7–10.) The other side of the chassis is empty.

Fabric OS firmware v4.4.0 or later is already installed on the new SAN Director 2/128 CP cards.

The result of the procedure is a system populated with four Core Switch 2/64 port cards in slots

1 through 4, two SAN Director 2/128 CP cards in slots 5 and 6, and four SAN Director 2/128 port

cards in slots 7 through 10 and configured with two domains.

Consider the following rules and guidelines:

Because this procedure requires power reset and rebooting, traffic on the fabric is disrupted.

You should be familiar with the standard procedures for shutting down the equipment. Refer to the HP

StorageWorks Core Switch 2/64 and SAN Director 2/128 installation guide, which contains more

details on disconnecting an HP StorageWorks model from the network and fabric.