Environmental requirements, Supported sfps, Supported hbas – HP Brocade 8Gb SAN Switch for HP BladeSystem c-Class User Manual

Page 31

Advertising
background image

Table 9 8Gb SAN Switch physical dimensions

Measurement

Dimension

29.3 mm (1.15 in)

Height

208 mm (8.19 in)

Width

280 mm (11.02 in)

Depth

1.27 kg (2.8 lb)

Weight

Environmental requirements

To ensure proper operation, the switch must not be subjected to environmental conditions beyond
those for which it was tested. The ranges specified in

Table 10 (page 31)

list the acceptable

environment for both operating and nonoperating conditions.

Table 10 Environmental requirements

Acceptable range during non-operation

Acceptable range during operation

Condition

-40°C to 70°C with maximum rate of change
of 20 C /hr

104°F/40 °C at sea level, derated 1 C per
1000 ft above sea level

Ambient temperature

50% to 80% relative humidity, non-condensing

5% to 90% relative humidity, non-condensing

Humidity

0 to 40,000 ft (12 km) above sea level

0 to 10,000 ft (3 km) above sea level

Altitude

140 G, 2mS,

40 G, 2mS duration

Shock

2.0 G, 5–500 Hz

0.5 G, 10–500 Hz

Vibration

None required

47 cubic ft/minute

Airflow

Supported SFPs

Do not use unsupported SFPs. They may not fit correctly and may void your warranty. Any port
with an unsupported SFP will automatically be disabled by switch firmware, leaving the port
non-operational. See

“Supported SFP transceiver options” (page 9)

for a list of supported SFPs.

For a complete list of supported devices, refer to the latest version of the HP SAN Design Reference
Guide
at the HP website:

http://h18000.www1.hp.com/products/storageworks/san/documentation.html

Supported HBAs

For a list of HBAs that have been tested and are known to work with the SAN switches, see the
latest version of the HP SAN Design Reference Guide at the HP website:

http://h18000.www1.hp.com/products/storageworks/san/documentation.html

Environmental requirements

31