SYNC OUTPUTS (1 to 4)

These signals are optically isolated and require the user to provide a high voltage level
(USER VCC) and signal common (USER GROUND). USER VCC can be from 5V to
24V. ICC is a function of USER VCC and load resistor R. An example of the functional
circuit is indicated in the following diagram.

5V TO 24V

100K

V LOAD

442R

PIN 10. USER VCC

R

VCC-USER

GND-USER

SY NC OUT

USER TRIGGER
CIRCUIT

T4

CAMERA
CIRCUIT

T2

TLP281-4GB

1

2

16

15

T3

IF = 5mA

CAMERA
LOGIC SIGNAL

3.3V CAMERA
LOGIC SIGNAL

SYNC OUT
SIGNAL

T1

Various USER VCC values and load values for the above circuit are indicated in the
following table:

USER

VCC

USER

ICC

R

LOAD

V LOAD

R POWER

DISSIPATION

T1

T2

T3

T4

5V

8mA 500

4.1V

32mW

1.5

µ

s 6.5

µ

s 2

µ

s 14

µ

s

5V 4.8mA 1K

4.8V

23mW

1.5

µ

s 5

µ

s 17

µ

s 40

µ

s

12V 9.2mA 1.2K

11.2V

101mW

1.5

µ

s 11.2

µ

s 2

µ

s 20

µ

s

12V 4.9mA 2.4K

11.8V

58mW

1.5

µ

s 8.5

µ

s 17

µ

s 55

µ

s

24V 9.5mA 2.4K

23.2V

217mW

1.5

µ

s 22

µ

s 2

µ

s 37

µ

s

24V 5mA 4.8K

23.8V

120mW

1.5

µ

s 12

µ

s 17

µ

s 105

µ

s

Advertising