Table 2 – HP StorageWorks 2.64 Director Switch User Manual

Page 43

Advertising
background image

Director Element Manager user guide

43

If a gray square displays in the status bar (no Ethernet connection), a reason for the status displays

in the Status table at the top of the Hardware view. See ”

Director Status table” on page 52

for

details. See

Table 2

for the meanings of status symbols that display in Element Manager views.

Table 2

Operating status—status bar and director Status table

Symbol

Status bar Director Status table text Description

Green

Circle

Fully Operational

All components and installed ports are

operational; no failures.

Yellow

Triangle

Redundant Failure

A redundant component has failed,

such as a power supply, and the

backup component has taken over

operation.

Minor Failure

A failure occurred which has decreased

the director operational ability. Normal

switching operations are not affected.
One or more Port cards failed, but at

least one Port card is still operational.
A fan has failed or is not rotating

sufficiently.
One of two CTP cards failed.
One of two SBAR cards failed.

Red and

Yellow

Diamond

NOT OPERATIONAL

A critical failure prevents the director

from performing fundamental switching

operations.
All fans fail.
Both SBAR cards fail.
All installed Port cards fail.

Gray

Square

Never Connected
Link Timeout
Protocol Mismatch
Duplicate Session
Unknown Network

Address
Incorrect Product Type

Director status is unknown. This occurs if

the Ethernet network connection

between the HAFM appliance and the

director cannot be established or if the

CTP fails. See

Director Status table” on

page 52

for details on the status table

text.