HP StorageWorks XP Remote Web Console Software User Manual

Page 101

Advertising
background image

Table 40 Error Code and Error Contents When Operating RAID Manager (continued)

Error Contents

Error Code (SSB2)

Error Code (SSB1)

Because the volume specified as the S-VOL was the source volume of
XP Auto LUN, the pair operation was rejected.

234b

Because the specified P-VOL and the S-VOL for XP Business Copy pair
operations was not a pair, the pair operation was rejected.

2350

Because the volume specified as the P-VOL and the volume specified
as the S-VOL was the same one, the pair operation was rejected.

2351

Because the specified P-VOL and S-VOL was online to the host, the
quick restore operation or the reverse copy operation was rejected.

2352

Because the specified P-VOL and S-VOL was being split by using quick
split, the pair deletion was rejected.

2353

Because the P-VOL and S-VOL were being split by using steady split,
the pairresync operation was rejected.

2354

b9a0/b9a1/b9a2/

b9a5/b9a6/b9ae/

The pair creation was rejected because the volume specified as the
S-VOL was the P-VOL of the splitting pair or the P-VOL of the pair where

2357

b9af

the reverse copy operation or quick restore operation is being
performed.

Because the volume specified as the S-VOL was the P-VOL of the splitting
pair, the pairresync operation was rejected.

2358

The volume specified as a P-VOL was a P-VOL of an XP Continuous
Access synchronous or asynchronous pair. Because the status of the

235b

XP Continuous Access pair was not Suspend, the Reverse Copy or the
Quick Restore operation was rejected.

The volume specified as a P-VOL was an S-VOL of an XP Continuous
Access synchronous or asynchronous pair. Because the status of the

235c

XP Continuous Access pair was not Suspend, the Reverse Copy or the
Quick Restore operation was rejected.

The volume specified as an S-VOL was a P-VOL of an XP Continuous
Access synchronous or asynchronous pair. Because the status of the

235d

XP Continuous Access pair was not Suspend, the Reverse Copy or the
Quick Restore operation was rejected.

Because the volume specified as the P-VOL has the S-VOL Disable
attribute assigned by Data Retention Utility, the quick restore operation
or the reverse copy operation was rejected.

236C

Because the volume specified as the S-VOL has the S-VOL Disable
attribute assigned by Data Retention Utility, the pair operation was
rejected.

236D

Because the volume specified as the P-VOL was not mounted, the pair
operation was rejected.

2370

Because the volume specified as the P-VOL was blocked or a system
disk, the pair operation was rejected.

2371

Because the volume specified as the P-VOL was being formatted, the
pair operation was rejected.

2372

Because the volume specified as the P-VOL was a command device,
the pair operation was rejected.

2373

2380

1.

Because the volume specified as the S-VOL was not mounted, the
pair operation was rejected.

2.

Because the MU number was 3 or more, the pair operation was
rejected.

Troubleshooting When Using RAID Manager

101

Advertising