5 troubleshooting, Problem diagnosis, Problems during installation – HP StorageWorks 500 G2 Modular Smart Array User Manual

Page 31

Advertising
background image

5 Troubleshooting

This chapter discusses the following topics:

Problem diagnosis
Problems during installation
HBA failure
Cable failure

Problem diagnosis

If the problem is related to the multipath I/O, consult the Insight Management Agents and do one

of the following:

For Microsoft operating systems:
• Use the ProLiant Storage Manager or ProLiant Multipath Manager FAQs.
• Use the ProLiant Storage Manager with ProLiant Multipath Manager software, and the DME to

identify the I/O path status.

For Linux operating systems, enter the following command to identify HBA status, multipath status,

and I/O block transfer size:
cat /proc/mdstatus

Problems during installation

This section describes how to troubleshoot the most common problems encountered during software

installation.
To troubleshoot the problems encountered during installation, complete the following steps:

1.

In a Microsoft environment, uninstall any previous version of the multipath software first.

2.

Ensure that the firmware is upgraded for all HBAs and both the MSA500 G2 controllers, if

installed.

3.

Ensure that the hardware installation meets the

Minimum requirements

.

4.

Ensure that the SCSI cabling matches one of the

Supported four-node configurations

.

5.

Ensure that the HBA is functioning properly. See the appropriate server and HBA documentation.

If the HBA has failed, see

HBA failure

.

6.

Ensure that the SCSI cables are functioning properly. If a SCSI cable fails, see

Cable failure

.

7.

Ensure that you followed operating system-specific instructions:
• If the server has a Red Hat operating system, ensure that the active kernel is edited properly.
• If the server has a Microsoft operating system, ensure that the SCSI cable from the redundant

HBA is disconnected before Smart Array Multipath software installation.

IMPORTANT:

After establishing a redundant configuration and adding a logical volume, use Windows Disk

Manager to detect the new volume.

• If these steps do not solve the installation problem, contact an authorized reseller.

Smart Array Multipath software user guide

31