Preparing for a disk replacement – HP StoreVirtual 4000 Storage User Manual

Page 46

Advertising
background image

update before checking it again. If the status indicates the second drive is safe to remove, then it
can be replaced.

For example, if an array is Rebuilding, no other drives in the array (except for unused hot-spare
drives) are safe to remove. However, if the configuration includes two or more arrays and those
arrays are Normal, the Safe To Remove status indicates that drives in those other arrays may be
replaced.

Preparing for a disk replacement

Use this section to replace a single disk under the following conditions:

You know which disk needs to be replaced through LeftHand OS monitoring.

When viewed in the Disk Setup tab, the Drive Health column shows Marginal (replace as
soon as possible) or Predictive Failure (replace right away).

RAID is still on, though it may be degraded and a drive is inactive.

Use the instructions in

“Replacing disks appendix” (page 248)

for these situations:

If RAID is off

If you are unsure which disk to replace

The instructions in the appendix include contacting HP Support for assistance in either identifying
the disk that needs to be replaced or, for replacing more than one disk, the sequence in which
they should be replaced.

To prepare for disk replacement

Preparing for a disk replacement differs according to the RAID level of the storage system and
whether it is a hot-swap storage system. Carefully plan any disk replacement to ensure data safety,
regardless of whether the storage system is hot-swap. The following checklists outline steps to help
ensure data remains safe while replacing a disk.

Identify physical location of storage system and disk

Before beginning the disk replacement process, identify the physical location of both the storage
system in the rack and the disk in the storage system.

Know the name and physical location of the storage system that needs the disk replacement.

Know the physical position of the disk in the storage system. See

“Verifying disk status”

(page 37)

for diagrams of disk layout in the various storage systems.

Have the replacement disk ready and confirm that it is of the right size and has the right
carrier.

Best practice checklist for single disk replacement in RAID 1+0, RAID 5, and RAID 6

There are no prerequisites for this case; however, HP recommends that:

All volumes and snapshots show a status of Normal.

Any volumes or snapshots that were being deleted have completed deletion.

One of the following:

RAID status is Normal

If RAID is Rebuilding or Degraded, for storage systems that support hot-swapping of
drives, the Safe to Remove column indicates Yes (the drive can safely be replaced).

46

Configuring RAID and Managing Disks

Advertising