10 noncritical condition—backplane nvram read, 13 noncritical condition—backplane wwn is blank, I/o module conditions – HP 3000 Enterprise Virtual Array User Manual

Page 131: 45 i/o module element numbering

Advertising
background image

01. is the two-character

backplane

element number

ec is the error code

The only corrective action available for this error is to replace the drive enclosure.

8.2.01.10 NONCRITICAL condition—Backplane NVRAM read

An invalid NVRAM read occurred and an automatic recovery process has begun. This condition report is

active for 15 seconds.
If the automatic recovery process does not correct the problem, record all six characters of the condition

report, then contact your HP authorized service representative.

8.2.01.11 NONCRITICAL condition—Backplane NVRAM write failure

The system is unable to write data to the NVRAM. This problem prevents communication between

elements in the enclosure. This condition report is active for 15 seconds.
To correct this problem, record all six characters of the condition report, then contact your HP authorized

service representative.

8.2.01.12 NONCRITICAL condition—Backplane NVRAM read failure

The system is unable to read data from the NVRAM. This problem prevents communication between

elements in the enclosure. This condition report is active for 15 seconds.
To correct this problem, record all six characters of the condition report, then contact your HP authorized

service representative.

8.2.01.13 NONCRITICAL condition—Backplane WWN is blank

The system is unable to read valid data from the NVRAM. This report is active until corrected. This

condition can result in incorrect device location data being displayed.
To correct this problem, record all six characters of the condition report, then contact your HP authorized

service representative.

I/O Module conditions

The format of an I/O module condition report is 8.7.en.ec, where:

8.7. is the I/O module element type number

en. is the two-character I/O module element number (see

Figure 45

)

ec is the error code

CXO7951A

1

2

Figure 45 I/O module element numbering

1. I/O Module A (01)

2. I/O Module B (02)

Correction of an I/O module problem normally requires replacing the module. The following sections

define the I/O module problem by I/O module location.