Fibre address conversion tables, Fibre address conversion – HP XP Racks User Manual

Page 55

Advertising
background image

Fibre address conversion tables

Table 15 (page 55)

,

Table 16 (page 55)

,

Table 17 (page 56)

and show the fibre address conversion

tables:

Table number 0 = HP-UX systems (see

Table 15 (page 55)

)

Table number 1 = Solaris and IRIX systems (see

Table 16 (page 55)

)

Table number 2 = Windows systems (see

Table 17 (page 56)

)

The conversion table for Windows systems is based on the Emulex driver. If a different fibre-channel
adapter is used, the target ID indicated by the raidscan command may be different than the target
ID indicated by the Windows system.
Note on Table 3 for other Platforms: Table 3 is used to indicate the LUN without Target ID for
unknown FC_AL conversion table or fibre-channel fabric (fibre-channel world wide name). In this
case, the Target ID is always zero, thus Table 3 is not described in this document. Table 3 is used
as the default for platforms other than those listed above. If the host will use the WWN notation
for the device files, then this table number should be changed by using the $HORCMFCTBL variable.
If the TID displayed on the system is different than the TID indicated in the fibre address conversion
table, you must use the TID (or LU#) returned by the raidscan command to specify the device(s).

Table 15 Fibre Address Conversion Table for HP-UX Systems (Table0)

C7

C6

C5

C4

C3

C2

C1

C0

TID

AL-PA

TID

AL-PA

TID

AL-PA

TID

AL-PA

TID

AL-PA

TID

AL-PA

TID

AL-PA

TID

AL-PA

0

25

0

3A

0

55

0

72

0

98

0

B2

0

CD

0

EF

1

23

1

39

1

54

1

71

1

97

1

B1

1

CC

1

E8

2

1F

2

36

2

53

2

6E

2

90

2

AE

2

CB

2

E4

3

1E

3

35

3

52

3

6D

3

8F

3

AD

3

CA

3

E2

4

1D

4

34

4

51

4

6C

4

88

4

AC

4

C9

4

E1

5

1B

5

33

5

4E

5

6B

5

84

5

AB

5

C7

5

E0

6

18

6

32

6

4D

6

6A

6

82

6

AA

6

C6

6

DC

7

17

7

31

7

4C

7

69

7

81

7

A9

7

C5

7

DA

8

10

8

2E

8

4B

8

67

8

80

8

A7

8

C3

8

D9

9

0F

9

2D

9

4A

9

66

9

7C

9

A6

9

BC

9

D6

10

08

10

2C

10

49

10

65

10

7A

10

A5

10

BA

10

D5

11

04

11

2B

11

47

11

63

11

79

11

A3

11

B9

11

D4

12

02

12

2A

12

46

12

5C

12

76

12

9F

12

B6

12

D3

13

01

13

29

13

45

13

5A

13

75

13

9E

13

B5

13

D2

-

-

14

27

14

43

14

59

14

74

14

9D

14

B4

14

D1

-

-

15

26

15

3C

15

56

15

73

15

9B

15

B3

15

CE

Table 16 Fibre Address Conversion Table for Solaris and IRIX Systems (Table1)

C7

C6

C5

C4

C3

C2

C1

C0

TID

AL-PA

TID

AL-PA

TID

AL-PA

TID

AL-PA

TID

AL-PA

TID

AL-PA

TID

AL-PA

TID

AL-PA

112

25

96

3A

80

55

64

72

48

98

32

B2

16

CD

0

EF

113

23

97

39

81

54

65

71

49

97

33

B1

17

CC

1

E8

114

1F

98

36

82

53

66

6E

50

90

34

AE

18

CB

2

E4

Fibre address conversion tables

55

Advertising
This manual is related to the following products: