Message name / description

ASCQ

ASC

Sense
key

PARAMETER VALUE INVALID

Verify Mode Select page fields.

Verify that fields comply with command format described in this guide.

This response is also returned for commands issued to the diagnostic
interface of the library if an invalid parameter is sent.

Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.

Verify that the library and its components have the current firmware.

02

26

5

CLEANING CARTRIDGE INSTALLED
A cleaning cartridge cannot be removed from a drive because it is being
used in a cleaning operation. A cartridge cannot be placed into the drive
because the drive is being cleaned. A cartridge cannot be placed into
an empty storage element because it is reserved for a cleaning cartridge
that is currently in use in a drive cleaning operation.

03

30

5

SAVING PARAMETERS NOT SUPPORTED

Verify Save Parameter field in the Mode Select page complies with
the command format described in this guide.

Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.

Verify that the library and its components have the current firmware.

00

39

5

MEDIUM REMOVAL PREVENTED
Prevent Medium Removal command was executed and command was
received to export cartridge. Retry move command using your application
software.

02

53

5

TRANSFER FULL - COMMAND CAN NOT BE EXECUTED
Picker has cartridge in it.

Move cartridge to empty storage element using your application
software. Retry command.

As a last resort, manually remove the tape from the picker.

01

80

5

ELEMENT CONTENTS UNKNOWN
The contents of an element address are unknown. Re-inventory the library.

22

80

5

TRANSPORT FULL
The picker contains a cartridge.

Issue a command to retrieve the cartridge from the picker and place
it in either a bin or a tape drive.

As a last resort, manually remove the tape from the picker.

C0

81

5

PICKER INVALID START CONDITION
Picker hardware condition is unknown. Run the Robotics to Home Position
test from the OCP.

E0

81

5

PICKER INVALID COMMAND
Picker hardware commanded to position out of system mechanical limits.
Run the Robotics to Home Position test from the OCP.

F0

81

5

Sense data values