HP Linux Server Management Software User Manual

Page 53

Advertising
background image

Toolkit utilities 53

Error code

Error message

Comment or clarification

2824

Invalid expand priority.

This error message appears if the expand priority value
specified in the script is not supported. This message also
appears if expansion is not possible because the Expand Priority

feature is then not supported. (Expansion might be temporarily
unavailable on a controller that normally supports expansion if,
for example, the cache battery has low charge, another

expansion or migration is already in progress, or the array has
the maximum supported number of physical drives.)

2825

Invalid array.

The array ID is invalid.

2826

Array not specified.

The script file has commands that require an array, but no array
is specified.

2827

New array ID does not match
the next available array ID.

The scripted array ID is not the next ID in sequence, based on the
IDs of the existing arrays. For example, only array A exists and
the script file specifies creation of array C (omitting array B).

2828

New array ID already exists. This error occurs in Configure mode when the array ID specified

in the script file already exists in the configuration. In Configure
mode, you can create only new arrays.

2829

Cannot create array.

The controller has no unassigned physical drives, or it already
has the maximum number of arrays or logical drives.

2830

Cannot expand array.

The controller does not support expansion, or the current
controller configuration is not expandable.

2831

Cannot change array spare. This error message appears if you try to change the number of

spares in an array when the configuration does not support the
addition or subtraction of spares.

2832

Invalid physical drive.

A specified physical drive is not a valid physical drive, or it

cannot be placed in the array.

2833

Invalid spare.

A specified spare is not a valid spare drive, or it cannot be

placed in the array as a spare.

2834

Invalid logical drive.

2835

Logical drive not specified.

The script file has commands that require a logical drive, but no

logical drive is specified.

2836

New logical drive ID does not
match the next available

logical drive ID.

The script file specifies a logical drive ID that is not the first
unused ID in the sequence. For example, this message appears if

the controller has only logical drive 1 and the script file specifies
creation of logical drive 3 (omitting logical drive 2). A common

cause of this error is that the input file specifies nonsequential
logical drive numbers. In this case, change the logical drive
numbers in the input file so that they are sequential.

2837

New logical drive ID already
exists.

This error occurs in Configure mode when the logical drive ID
specified in the script file already exists in the configuration. In
Configure mode, you can create only new logical drives.

2838

Cannot create logical drive. The array has no free space, or the maximum number of logical

drives has already been reached.

2839

Cannot migrate logical drive

RAID.

The controller does not support RAID migration, or migration is

not possible with the current controller configuration.

2840

Cannot migrate logical drive

stripe size.

The controller does not support stripe size migration, or

migration is not possible with the current controller
configuration.

Advertising
This manual is related to the following products: