Used Realloc—Displays the number of sectors of the reallocation area that have been used by the physical

drive. The status of this item can be OK or Replace Drive. If the status is Replace Drive, replace the drive, or an

actual drive failure may occur in the future.
Because of the nature of magnetic disks, certain sectors on a drive may have media defects. The reallocation

area is part of the drive that the drive manufacturer sets aside to compensate for these defects. The array

controller writes information addressed from the unusable sectors to available sectors in the reallocation area. If

too many sectors have been reallocated, there may be a problem with the drive.

Spinup Time—Displays the time it takes for a physical drive to spin up to full speed. The Status of this item can

be OK or Replace Drive. If the status is Replace Drive, replace the drive, or an actual drive failure may occur in

the future.
Drives require time to gain momentum and reach operating speed. As cars are tested to go from 0 mph to 60

mph in X number of seconds, drive manufacturers have preset expectations for the time it takes the drive to spin

to full speed. Drives that do not meet these expectations may have problems.
The spinup time value is shown in tenths of a second. Thus, if the drive takes 12 seconds to spin up, the value

would be 120. The value may be 0 for this monitored item under one of the following conditions:

You are monitoring a physical drive that is part of the managed system's internal drive array storage, and

you use a warm boot to reset the monitored system. During a warm boot, the drives continue to spin.

You are monitoring a physical drive in an external storage system and you reset the managed server but not

the storage system.

The physical drive may be configured to start up immediately when the system is powered on, instead of

waiting for the controller to start it.

Problem Indicators

Use the Problem Indicators to determine when a drive failure has occurred that may be correctable without replacing

the drive. The Problem Indicators are:

Failed Recovery Reads—Shows the number of read errors that occurred while Automatic Data Recovery was

being performed from this physical drive to another drive. If a read error occurs, Automatic Data Recovery

stops.

Other Timeouts—Shows the number of times the drive did not respond with an interrupt within a controller-

defined period of time after a command had been issued. This monitored item does not include Data Request

(DRQ) timeouts.
If the other timeouts count is not zero and the drive has failed, the failure might be correctable without replacing

the drive. Verify the status of the drive by checking the following:

Ensure that all system and storage system cables are intact and seated properly. You may need to replace

the cables.

Ensure that a storage system is plugged in and powered on. Make sure the power supply is functioning.

IMPORTANT:

Never turn off a storage system when the attached system is still turned on.

Check the physical proximity of the system to other electrical devices. Since electrical noise may cause this

error, check the AC circuit for other electrical devices.
Timeouts can be caused when two or more drives are set to the same SCSI ID. Ensure that the storage

system and system SCSI IDs do not conflict.

On a storage system, check the SCSI ID cable on the drive tray. If the cable is damaged or incorrectly

installed, SCSI Timeouts can occur. See the documentation accompanying the Hot Plug Drive Tray Service

Spare Kit.

Ensure that the system temperature is within specified limits. Ensure that the fans are operating and are not

blocked.
In some instances, drive failure can cause Timeouts. If you continue to receive many of these errors, replace

the drive.

SCSI Bus Faults—Displays the number of times that SCSI bus parity, overrun, or underrun errors have been

detected on the SCSI bus. Since the controller retries the operation, SCSI bus faults can cause a drop in

performance, or, in some cases, data corruption.
If the count is not zero and the drive has failed, the failure might be correctable without replacing the drive.

Verify the status of the drive by checking the following:

Ensure that all system and storage system cables are intact and seated properly. You may need to replace

the cables.