Aube Technologies TH140-28 User Manual

Installation and user guide, Installation

Advertising
background image

TH140-28

400-140-000-C 2008-01-15 1/4

1.1 Guidelines

TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL SHOCK

.

Installation should be carried out by an electrician.

• For a new installation, choose a location about 5 ft. (1.5 m) above

the floor.

• The thermostat must be installed facing the heating system and on

an inside wall.

• Avoid locations where there are air drafts (top of staircase, air out-

let), dead air spots (behind a door), direct sunlight or concealed
chimneys or stove pipes.

n

Loosen the captive screw holding the faceplate to the mounting
plate.

o

Pull the lower part of the faceplate to remove it from the mount-
ing plate.

p

Loosen the screw (captive) holding the wire cover and remove
the wire cover.

q

Pull wires through the hole in the mounting plate and secure the
mounting plate to the wall (or onto an electrical box for line volt-
age wiring) using the enclosed wall anchors and screws.

r

Wire the thermostat to the heating system (see section 1.2) and,
if necessary, connect the remote input (see section 1.3).

s

Once wiring is complete, re-install the wire cover.

t

Use the switches located at the back of the faceplate to config-
ure your thermostat (see section 1.4) according to your applica-
tion.

u

Install the batteries (see section 1.5).

v

Mount the faceplate on the mounting plate and tighten the screw.

1.2 Thermostat Wiring

LOW VOLTAGE < 30 V

: no polarity

LINE VOLTAGE 120 to 240 VAC

Must be installed onto a certified electrical box.

For a 2-wire connection

: no polarity

For a 3-wire connection

: observe the polarity

n

Installation

1.

NORTH AMERICA

EUROPE

Connection to a
circulator through
a 24 V relay

Connection to the
thermostat terminals
of a furnace

120/240 V

Relay

24 V transformer

Relay

Furnace

Connection to a
circulator (pump)
of a water heating
system

2 A maximum load

120/240 V

Power supply

Load

Provided wires

Direct wiring to
the circulator

Connection to the
thermostat terminals
of a furnace

240 V

Furnace

Relay

Wiring to a
power-operated
mixing control valve

240 V

TH140-28

Installation and User Guide

Electronic Programmable Thermostat

400-140-000-C (TH140-28) ENG.fm Page 1 Tuesday, January 15, 2008 1:46 PM