Installation Instructions

DUCTWORK CALCULATIONS

Calculate Total Equivalent Ductwork Length

Equivalent

Number

Equivalent

Duct Pieces

Length* x

Used =

Length

6” round

straight

1 ft.

x

( )

=

ft.

3

1

4

” x 10"

straight

1 ft.

x

( )

=

ft.

6”, 90°

elbow

15 ft. x

( ) =

ft.

6”, 45°

elbow

9 ft.

x

( )

=

ft.

24” max.

flexible

metal offset

adapter

34 ft. x

( )

=

ft.

3

1

4

” x 10”

90° elbow

16 ft. x

( ) =

ft.

3

1

4

” x 10”

45° elbow

5 ft.

x

( )

=

ft.

3

1

4

” x 10”

90° flat elbow 18 ft. x

( )

=

ft.

6” round

to 3

1

4

” x 10”

transition

7 ft.

x

( ) =

ft.

Subtotal Column 1 =

ft.

* Equivalent lengths of duct pieces are based on actual

tests and reflect requirements for good venting

performance with any downdraft cooktop.

† Measure and list feet of straight duct used. Count and

list the quantity of all other duct pieces for the “Number

Used” of each type.

IMPORTANT:
For maximum efficiency, use the shortest and straightest

duct run possible, with as few fittings as possible.

For satisfactory performance, the duct run should not

exceed 100 feet equivalent length.
Venting performance is improved by using larger

diameter duct.

Equivalent

Number

Equivalent

Duct Pieces

Length* x

Used =

Length

6” round

to 3

1

4

” x 10”

transition

90° elbow

20 ft.

x

( ) =

ft.

3

1

4

” x 10”

to 6” round

transition

5 ft.

x

( ) =

ft.

3

1

4

” x 10”

to 6” round

transition

90° elbow

12 ft. x

( )

=

ft.

6” round

wall cap

with damper 21 ft.

x

( ) =

ft.

3

1

4

” x 10”

wall cap

with damper 27 ft.

x

( ) =

ft.

6” round

roof cap

20 ft. x

( ) =

ft.

6” round

roof vent

24 ft.

x

( ) =

ft.

Subtotal Column 2 =

ft.

Subtotal Column 1 =

ft.

TOTAL DU CTWORK =

ft.

Should not exceed 100 feet.