About the controls on the air conditioner, Vent control, Air direction – GE AJCQ08ACF User Manual

Page 8: Cool only models heat/cool models 8

Advertising
background image

About the controls on the air conditioner

Vent Control

The vent control is located behind the front grille on the right

side of the air discharge area. When CLOSED, only the air

inside the room will be circulated and conditioned. When

OPEN, the vent allows outdoor fresh air exchange.
To open or close the vent:

1. Remove the front grille.

2. Remove the vent card screw.

3. Remove vent card, turn it over and replace it by locating

rear hole in card over locating pin inside air discharge and

reattaching screw at front.

Horizontal louvers

on the front grille let you

control the air direction

up and down.

Remove the front grille to adjust

the vertical louvers side-to-side

to direct the air left

or right.

Air Direction

Locating hole

Screw hole

OPEN position

(Mesh end toward back)

CLOSE position

(Mesh end toward front)

Locating hole

Screw hole

The unit leaves the factory set at the CLOSE position.

No function (reserved

for future use)

Auxiliary Controls – Dip Switches (location varies by model)

The auxiliary dip switch controls are
ORFDWHGEHKLQGWKHURRPFDELQHW³DV

shown in this figure.
The owner is responsible for checking

switches and ensuring they are in the

desired position.

Fan Cycle/Continuous - Cool

Fan Cycle/

Continuous - Heat

Class 2

ON

ON

OFF

ON

ON

COOL

FAN

HIGH

MED

OFF

OFF

SLEEP

MODE

TIMER

TEMP

+

-

Filter Reminder

Function

Auxiliary Controls – Dip Switches (location varies by model)

The auxiliary dip switch controls are located
EHKLQGWKHURRPFDELQHW³DVVKRZQLQWKLVILJXUH

The owner is responsible for checking switches

and ensuring they are in the desired position.

Fan Cycle/Continuous - Cool

Fan Cycle/Continuous - Cool

Filter Reminder Funtion

When this switch is enabled (RIGHT), it allows the indoor

fan to cycle on/off with the compressor. When this

switch is disabled (LEFT), it allows the indoor fan to run

continuously. The default setting is right (fan cycle).

When this switch is enabled (RIGHT), an LED will light

up the user interface after 250 of accumulated fan run

time. It serves as a reminder to clean the filter. When

this switch is disabled (LEFT), the function is disabled.

The default setting is right (enabled).

ON

ON

Fan Cycle/Continuous - Cool

Filter Reminder Function

Cool Only Models

Heat/Cool Models

8