Dsks433eb, Ge spacemaker, Stationary dryer – GE DSKS433EBWW User Manual

Page 3: Dsks433ebww

Advertising
background image

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

ge.com or call GE Answer Center

®

service,

800.626.2000.

360432

Specification Revised 5/09

Listed by

Underwriters

Laboratories

DSKS433EB

GE Spacemaker

®

Stationary Dryer

Dimensions and Installation Information (in inches)

For complete information, see installation instructions packed with your dryer.
Ducting Materials:

For best performance, this dryer should be vented with 4" diameter all rigid metal
exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid)
ducting can be used (Kit WX08X10077). In special installations, it may be necessary to
connect the dryer to the house vent using a flexible metal (foil-type) duct. A UL-listed
flexible metal (foil-type) duct may be used ONLY in installations where rigid metal or
flexible metal (semi-rigid) ducting cannot be used AND where a 4” diameter can be
maintained throughout the entire length of the transition duct. Please see installation
instruction packed with your dryer for complete instructions when using flexible metal
(foil type) ducting.

Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the

side or bottom of dryer, add one turn.

2. The maximum length of 4' rigid (aluminum or galvanized) duct which can be tolerated

is shown in the table.

A turn of 45° or less may be ignored. Two 45° turns within the duct length should be

treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.

Dryers

must be exhausted to the outside.

Caution: For personal safety do not terminate exhaust into a chimney, under any
enclosed house floor (crawl space), or into an attic, since the accumulated lint could
create a fire hazard or moisture could cause damage. Never terminate the exhaust into
a common duct or plenum with a kitchen exhaust, since the combination of lint and
grease could create a fire hazard.

Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird
nesting, etc. The wall cap must also be located at least 12" above the ground or any
other obstruction with the opening pointed down.

Dryer Note: Dryer wall outlet must be located within 36" of service
cord entry and accessible when dryer is mounted in position.

DSKS433EBWW

80

100

10

90

OFF

OFF

60

50

40

30

20

70

PERM. PRESS & DEL

ICATES CYCLE

T I M E D CYC L E

PUSH TO START

AU TO

R EG U L A R

TEMPERATURE

REGULAR

(HIGH HEAT)

PERM PRESS

(MED. HEAT)

DELICATES

(LOW HEAT)

FLUFF

(NO HEAT)

*

OFF

cool down

cool

down

*

33-1/4

24-1/2

23-7/8

Advertising