24" unitized spacemaker, 2 doe cu. ft. washer and 4.4 cu. ft. dryer, Gtup240em/gm dryer exhaust length – GE GTUP240GMWW User Manual

Page 2

Advertising
background image

Dimensions and Installation Information (in inches)

360329

GTUP240EM/240GM

GE

®

24" Unitized Spacemaker

®

2.2 DOE Cu. Ft. Washer and 4.4 Cu. Ft. Dryer

Listed by

Underwriters

Laboratories

Specification Revised 10/13

For complete information, see installation instructions packed with your dryer.
Ducting Materials:

This dryer MUST be vented with 4" diameter all rigid metal exhaust duct.
Exhaust Length Calculation:

1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer,

add one turn.

2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown in the table.
For every extra 90° elbow, reduce the allowable vent system length by 10 ft.
Two 45° elbows will be treated like one 90° elbow.
For the side exhaust installations, add one 90° elbow to the chart.
The total vent system length includes all the straight portions and elbows of the system (transition duct

included).
Dryers

must be exhausted to the outside.

Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl

space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage.

Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint

and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap

must also be located at least 12" above the ground or any other obstruction with the opening pointed down.

Special Installation Requirements
Alcove or Closet Installation:

• If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.

• The dryer MUST be exhausted to the outside.

• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:

0" both sides and rear

1" front and top

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 75-1/2".

• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area

equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in.

of open area equally distributed.

• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:

• The dryer MUST be exhausted to the outdoors.

• The installation must conform with the local codes, or in the absence of local codes, with the National Electric

Code and National Fuel Gas Code, ANSI Z223 for gas dryers.

Minimum Clearances other than Alcove or Closet Installation:

• Minimum clearances to combustible surfaces

0" both sides and rear

1" front and top

6

GTUP270EM/GM and GTUN275EM/GM

DRYER EXHAUST LENGTH

4" DIA.

4"

4" DIA.

4" DIA.

2-1/2"

RECOMMENDED MAXIMUM LENGTH

Exhaust Hood Types

Recommended

No. of 90º

Elbows

Rigid

Metal

Rigid

Metal

56 Feet

44 Feet

34 Feet

24 Feet

0

1

2

3

42 Feet

32 Feet

25 Feet

18 Feet

Use only for short

run installations

GTUP240EM/GM DRYER EXHAUST LENGTH*

4" DIA.

4"

4" DIA.

4" DIA.

2-1/2"

RECOMMENDED MAXIMUM LENGTH

Exhaust Hood Types

Recommended

No. of 90º

Elbows

Rigid

Metal

Rigid

Metal

43 Feet

33 Feet

24 Feet

0

1

2

36 Feet

26 Feet

16 Feet

Use only for short

run installations

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

geappliances.com or call GE Answer Center

®

service, 800.626.2000.

Advertising
This manual is related to the following products: