Important, Finish the wall opening – GE AEM18DP User Manual

Page 13

Advertising
background image

13

7KURXJKWKH:DOO,QVWDOODWLRQ,QVWUXFWLRQV³2SWLRQDO

The case may be installed through-the-wall in

both existing and new construction.
Read completely, then follow step-by-step.
NOTE: Obtain all materials locally for mounting

the air conditioner through-the-wall.

IMPORTANT

Through-the-wall installation is not appropriate

if any of the side or top louvers in the case will

be obstructed by the wall.
All side and top louvers in the case must project

on the outdoor side of the wall.
The room side of the case must project

into the room far enough to maximize the

balance of the unit.
The case must be installed level from side-to-

side and with a slight tilt from front to rear. Use

a level; no more than a 1/2 bubble will be the

correct case slant to the outside.

/LQWHODQJOHLVUHTXLUHGWRVXSSRUWEULFNVRU

blocks above opening.

)ODVKLQJLVUHTXLUHGDQGVKRXOGH[WHQGWKH

length of the opening to ensure no inside cavity

leakage occurs.
Remove the air conditioner from the case.

For specific instruction, refer to the Window

Installation Instructions.
Make certain that a wall receptacle is

available close to the hole location or make

arrangements to install a receptacle.

Place the case in the wall opening and

place wood support strips between the case

bottom and the flashing on both sides of the

bottom rail. They should be the same height as

the bottom rail and the same length as the wall

opening.

1

A

B

FINISH THE WALL OPENING

Caulk all four sides on the outdoor side of the

case to prevent moisture from getting through

to the interior wall. Use of flashing (drip rail) will

further prevent water from dripping inside the

wall and down the outside of the building.

Place the air conditioner into the case.

For specific instruction, refer to the Window

Installation Instructions.

2

IMPORTANT

(cont.)

Secure with 14 wood screws anchored at least an

inch into the wall support structure.
NOTE: Drill pilot holes, if necessary, for proper

installation. If the frame is oversized, use shims to

prevent case distortion.

1

D

A

B

Lintel angle

Plaster line

Trim molding (if

desired)

INSIDE

Bottom rail

Wood filler and

caulking (above and

below the flashing)

Air louvers (top

and sides must

project on the

outdoor side of

the wall)

OUTSIDE

Flashing

(Drip rail)

Case

bottom

Bottom

rail

Flashing

(Drip rail)

Wood support strips

Caulking

C

Advertising