Make the l.p. gas conversion, Adjust pressure regulator, Adjust burner orifice – GE JGRS06BEJBB User Manual

Page 7: Adjust oven burner, Check flame size, Warning, Caution, Adjust pressure regulator from natural gas to l.p, Adjust burner orifice from natural to l.p. gas, 2adjust oven burner

Advertising
background image

7

Installation Instructions

MAKE THE L.P. GAS CONVERSION

CHECK FLAME SIZE

Check the inner cone of
the flame. It should be
approximately 1/2

″ to 3/4″

long for the oven and
broil burners.

If the flame size is too
long, use a 1/2

″ open end

wrench or adjustable joint
pliers to adjust the orifice
hood, by turning in the natural direction.

WARNING:

If you attempt to

measure the inner cone of the flame,
please use caution; burns could result.

4

WARNING:

If you are using L.P.

(bottled) gas, all the adjustments described
below must be made before you make any
burner adjustments or use the oven.

WARNING:

This conversion must

be performed by a qualified installer or gas
supplier in accordance with the
manufacturer’s instructions and all codes
and requirements of the authority having
jurisdiction. Failure to follow instructions
could result in serious injury or property
damage. The qualified agency performing
this work assumes responsibility for the
conversion.

NOTE: Disconnect all electrical power and turn
off the gas supply at the shut-off valve before
beginning the conversion.

ADJUST PRESSURE
REGULATOR FROM NATURAL
GAS TO L.P.

Locate and remove regulator cover and wire
clip.

Locate the regulator and unscrew the cap.

Turn the retainer over so L.P. is showing on
the bottom of the retainer.

Replace the cap.

Replace the regulator cover.

E

D

C

B

A

1

NAT.

l..P.

ADJUST BURNER ORIFICE
FROM NATURAL TO L.P. GAS

CAUTION:

The adjustments in the

next column must be made before turning
on the burners. Failure to do so could result
in serious injury due to high flames and
toxic fumes.

Open the oven door.

Remove the oven bottom.

Remove the oven baffle (flame spreader).

C

B

A

2

ADJUST OVEN BURNER

Use a 1/2

″ open end or adjustable wrench to turn

the orifice hood in the L.P. direction, about 1 1/2
turns, until snug.

IMPORTANT: Do not overtighten or you may
bend the orifice hood or needle.

3

Oven Bottom
Burner Baffle

NAT. – L.P.
Adjustment
Made To Orifice Hood

L.P.

NAT.

Air Shutter

1/2

to 3/4

Inner Cone

of Flame

Pressure

Regulator

Adaptor

Flexible Connection

Remove

Wire Clip

Spring

Retainer

Gasket

NAT.

Cap

L.P.

Remove Regulator Cover

Advertising