GE ZSC2201NSS User Manual

Page 2

Advertising
background image

monogram.com

21

Abov

e-the-cook

top

A

dv

antium

Speedcook

ov

ens

m

icr

ow

av

e ov

ens

m

icr

ow

av

e ov

ens

w

arming draw

er

s

monogram.com

A

dv

antium

®

Speedcook

w

all ov

ens

Cutout and product dimensions

Advantium 240 oven installed alone
Order a 30"-wide single oven cabinet or cut the opening in
a wall to the dimensions shown.

30"

23-1/2"

19"

29-3/4"

25-1/4"

Min.

17-1/2"

36-3/4"

Min.

21-1/2"

Recessed

Depth

Construct

Base
Min. 3/8"

Plywood

Supported

by 2x4 or 2x2

Runners all

Four Sides

Advance planning for wall ovens with Advantium 240
Speedcook technology

Advantium 240 oven installed above a Monogram
warming drawer
An anti-tip block must be installed at the rear of the
warming drawer opening. Again, see installation
instructions for complete details.

• The warming drawer must be supplied with a separate

120V, 60Hz, properly grounded receptacle.

Advantium 240 oven installed above a Monogram single wall
oven and a warming drawer
An anti-tip block must be installed at the rear of the warming
drawer opening. See installation instructions for complete details.

• The Advantium oven and single oven combination must use

separate electrical junction boxes.

• The warming drawer must be supplied with a separate

120V, 60Hz, properly grounded receptacle.

Note: Additional
clearance between
cutouts may be
required. Check to be
sure the oven supports
above the warming
drawer location do not
obstruct the required
interior 23-1/2" depth
and 9-1/4" height. See
each specific product’s
installation instructions
for details.

30"

23-1/2"

17-1/2"

45-1/4"

Min.

Construct Solid

Bottom Min. 3/8"

Plywood

Supported by

2 x 4 or 2 x 2

Runners all

Four Sides

2" Min.

Per Oven

Requirement

2" Min.

Per warming drawer requirement

25-1/4"

36-3/4" Min.

530Dia13

30"

23-1/2"

Construct Solid

Bottom Min. 3/8"

Plywood

Supported by

2 x 4 or 2 x 2

Runners all

Four Sides

2" Min.

Per Warming

Drawer

Requirement

25-1/4"

17-1/2"

Advantium 240 oven installed above a Monogram single
wall oven
When installed over a single oven or a warming drawer, allow at
least 2" between the two openings. This separation will provide
clearance for bottom overlap of the Advantium oven and top
overlap of the single oven or warming drawer.

• The Advantium oven and single oven combination must use

separate electrical junction boxes.

The Monogram

®

Advantium built-in oven can be installed directly

into a wall or 30"-wide wall oven cabinetry. Install it alone, with a
single oven or with a warming drawer. Create a complete
cooking center by installing the Advantium with both.

• This oven must be installed at least 36-3/4" above the floor.

• For personal safety, this oven cannot be installed in a cabinet

arrangement such as an island or peninsula.

• This oven is not approved for installation below a countertop,

side by side or stacked.

Electrical requirements

Product rating is 208/240V, 60Hz, 30 amps. This product must be
connected to a supply circuit of the proper voltage and frequency
and protected by a time-delay fuse or circuit breaker.

Note:
Additional
clearance
between
cutouts
may be
required.

Installation note:
The Advantium 240 ovens now have the same cutout
dimensions as the 120 Advantium. If replacing an older
Advantium 240 oven (ZSC2001F or ZSC2001C), choose the new
integrated ZSC2201NSS and the matching storage drawer,
ZX2201NSS. Installed together, they fit perfectly into the old
Advantium 240 cutout. See combined Advantium and accessory
cutout dimensions on the next page.

30"

23-1/2"

36-3/4" Min.

45-1/4"

Recommended

Construct Solid

Bottom Min. 3/8"

Plywood

Supported by

2 x 4 or 2 x 2

Runners, all

Four Sides

2" Min.

Per Oven

Requirement

17-1/2"

25-1/4"

* The middle rail

separating the
two openings
may need to be
larger than the
2" min. shown.

Advertising
This manual is related to the following products: