Additional clearances
Installations without a hood require 48" minimum to combustibles above the 
rangetop. A custom hood installation with exposed horizontal combustible
surfaces must have an “ auto-on” feature. See hood installation instructions for
specific hood clearances.

The surface of the entire back wall above the countertop and below the hood
must be covered with a non-combustible material such as metal, ceramic tile,
brick or stone.

Advance planning for 48" Professional gas rangetops

Product dimensions and clearances

A 54"- or 48"-wide Professional vent hood with a minimum 
1200 CFM is recommended for installation over this rangetop.

Backsplash accessories

The rangetop requires a 12" minimum clearance to a 
vertical combustible surface at the rear. A backsplash
is required for installations with less than 12" 
clearance. The following backsplash accessories are
available, or a custom, non-combustible backsplash
can be used.

ZX12B48PSS, 12" backsplash
ZXADJB48PSS, 30"–36" adjustable-height backsplash 
with warming shelf

Allow 8" of free space below the 
top surface of the countertop.
Allow additional clearances
below the burner box to install
the regulator and make house
supply connections.

Note: 12”

from the top

of the shelf to

the top of the

backsplash

Control panel projects forward
from standard-depth cabinets.

Front of deep cabinets can align
with control panel beveled edge.

* The opening between a 4"- 

high backsplash must be 48" 
to allow the rangetop to slide
back against the wall.

Side view with a backsplash

Include the overhang of the rear trim when countertop continues behind the product. The overhang is decorative
only. The weight of the rangetop is fully supported by the side trims.

* Minimum cabinet cutout depth from the back of the rear trim to the back finished edge of the control panel—typically, 

the minimum cabinet depth (front to back). Maximum cabinet cutout depth is 26" minus the countertop overhang.

** Minimum cabinet cutout depth from the back of the rear trim to the back edge of chamfer at the sides of the control 

panel—typically, the maximum countertop cutout depth (front to back). Maximum countertop cutout depth is 25-1/4". 

Installation options

Note: Venting Recommendation
An HVI Certified vent hood or downdraft vent of the same or greater
width having 350 CFM minimum is recommended. 