Installation Instructions

B4 Three-Conductor Branch

Circuit Connection

When connecting to a three-conductor branch
circuit, if local codes permit:

a. Connect the bare oven ground conductor

with the crimped neutral (white) lead to
the branch circuit neutral (white or gray
in color), using a wire nut.

b. Connect the oven red lead to the branch

circuit red lead in accordance with local
codes, using a wire nut.

c. Connect the oven black lead to the branch

circuit black lead in accordance with local
codes, using a wire nut. If the residence
red, black or white leads are aluminum
conductors, see WARNING on page 14.

d. Install Junction Box Cover.

B3 New Construction and

Four-Conductor Branch
Circuit Connection

• When installing in new construction, or

• When installing in a mobile home, or

• When installing in a recreational vehicle, or

• When local codes do not permit grounding

through neutral:

a. Cut the neutral (white) lead from the crimp.

Re-strip the neutral (white) lead to expose
the proper length of conductor.

b. Attach the appliance grounding lead (green

or bare copper) in accordance with local
codes. If the residence grounding conductor
is aluminum, see WARNING on page 14.

c. Connect the oven neutral (white) lead to

the branch circuit neutral (white or gray)
in accordance with local codes, using a
wire nut.

d. Connect the oven red lead to the branch

circuit red lead and the oven black lead to
the branch circuit black lead in accordance
with local codes, using wire nuts. If the
residence red, black or white leads are
aluminum conductors, see WARNING
on page 14.

e. Install Junction Box Cover.

Ground
Wire

Junction Box
Cover

Junction Box
Cover

Ground and
Neutral Wires