GE ZDWR240PBS User Manual

Page 3

Advertising
background image

118

Reversible door swing

Models ZDWI240WII, ZDWC240NBS, ZDWR240PBS, ZDBI240WII,
ZDBC240NBS and ZDBR240PBS are shipped for a right-hand door
swing. The door swing may be reversed, with no kits required.

Privacy-glass wine reserves ZDWT24OPBS, and beverage centers
ZDBT240PBS, have a right-hand door swing. They cannot be
reversed.

Door swing clearances

All Monogram refrigeration modules are factory set for a
110° door swing.
When installed in a corner:
• Allow the minimum door swing clearances shown.

• The minimum clearance shown at 90° will allow full extension

of drawers and shelves.

Location requirements

All Monogram refrigeration modules may be closed in on
the top and sides as long as the front is unobstructed for air
circulation and door swing.

• Do not install these products where the temperatures will

go below 55°F (13°C) or above 90°F (32°C).

• Do not install where they will be subject to direct

sunlight, heat or moisture.

• These products are not designed to be stacked one over

the other.

Electrical
A 120V, 60HZ., 15- or 20-amp power supply is required. An
individual properly grounded branch circuit or circuit breaker is
recommended. Install a properly grounded 3-prong electrical
receptacle recessed into the back wall as shown. Electrical
must be located on rear wall as shown.

Note: GFCI (ground fault circuit interrupter) is not recommended.

The serial plate is located on the inside ceiling.

Side-by-side installation

For a complete refreshment center, install a Monogram wine
reserve and beverage center together.

• Products must operate from separate properly

grounded receptacles.

Advance planning for wine reserves and beverage centers

The installation space

The Monogram

®

wine reserves and beverage centers may be

installed beneath a countertop or can be used free-standing.

• If installing between frameless cabinets, a 1/2"-wide filler

strip or side panel may be required. The filler strip will act as
a spacer between the door case and adjacent cabinet and
will prevent interference with cabinet door swing. The width
of the opening must include filler panels.

34-1/2"-35"

24" Min.

23-3/4"

23-3/4" Min.

25-1/2"

Including

Handle

34-1/4"-

34-3/4"

23-3/4" Stainless steel

models

24-1/8" Framed models

1-1/2"

Locate Outlet

9"

Max.

10-1/2"

Note: When installed, the door should project forward 1" of
adjacent 24"-deep cabinets. Custom-framed models will project
forward 1-3/4" of adjacent cabinets.

Custom panel frame

Models ZDWI240WII and ZDBI240WII require a custom panel
frame surrounding the glass. The panel frame may be either
29-3/4" or 30" high. A 30" panel requires a notch cut into the
bottom of the panel to avoid interference with the hinge.

A

Minimum to Wall

110

°

110

° Door

Swing

21-5/8"

23-5/8"

B

Minimum to Wall

90

°

90

° Door

Swing

10"

Minimum to Wall

4"

Minimum to wall

* 95° door swing on custom

frame models.

*

Note: A solid panel that covers the door glass CANNOT be
installed on these models.

Note: Right-hand models
illustrated. Cut notches for
hinge clearances on the
opposite side for left-hand
door swing.

23-1/8”

29-3/4”

GLASS

25-1/4”

3/4” Thick Custom Panel,

Back Side

18-5/8”

2-1/4”

wide,

all sides

Rout the

back side

of the

opening

7/16”deep,

1-1/8” wide

23-1/8”

30”

GLASS

25-1/4”

18-5/8”

2-1/4”

Route the back

side of the

opening 7/16”

deep, 1-1/8” wide

Cut the notch

1/8” deep, 1/4”

wide and 1/4”

high

2-1/4”

1/8”

1/4”

1/4”

2-1/4”

2-1/2” at

bottom

Option 1

Option 2

Choose Option 1 or Option 2 panel frame size depending on
cabinetry size or style.

Advertising
This manual is related to the following products: