Location requirements

All Monogram refrigeration modules may be closed in on
the top and sides as long as the front is unobstructed for air
circulation.

• Do not install these products where the temperatures will

go below 55°F (13°C) or above 90°F (32°C).

• Do not install where they will be subject to direct

sunlight, heat or moisture.

• These products are not designed to be stacked one over

the other.

Electrical
A 120V, 60HZ., 15- or 20-amp power supply is required. An
individual properly grounded branch circuit or circuit breaker
is recommended. Install a properly grounded 3-prong electrical
receptacle recessed into the back wall of the installation
opening. See cutout illustration.

The serial plate is located below the bottom drawer liner on
the left side.

Note: GFCI (ground fault circuit interrupter) is not recommended.

Side-by-side installation

For the ultimate in convenience, install two double-drawer
refrigerators together.

• Products must operate from separate properly

grounded receptacles.

3/4" custom panels for

double-drawer refrigerator

Field-installed overlay drawer panels are required for
model ZIDI240WII.

• The overlay panel must be secured to a 1/4"-thick backer

panel that slides into the drawer trim. A 0.10"-thick spacer
panel must be placed between the overlay and backer panel.

• Custom handles of your choice must be installed onto the

assembled overlay panels.

Advance planning for double-drawer refrigerator

Overlay

Panel

1/4"

Backer

Panel

Door

3/4" custom panels for

fresh food and bar refrigerator

3/4" custom panels for

double drawer refrigerator

.10 Inch

Spacer

B

A

1/4" Gap

12-1/2 lbs. max.

B

12-1/2 lbs. max.

3/8

3/4

Right

side

view

of

overlay
custom

panel

Route

for hinge

clearance

Front

7/8

3/8

Top

view

of

overlay
custom

panel

Route

for hinge

clearance

Front

A

B

Spacer Panel

Backer Panel

Overlay Panel

Overlay

Panel

1/4"

Backer

Panel

Door

.10 Inch

Spacer

Spacer Panel

Backer Panel

Overlay Panel

Overlay

Panel

1/4"

Backer

Panel

Door

3/4" custom panels for

fresh food and bar refrigerator

3/4" custom panels for

double drawer refrigerator

.10 Inch

Spacer

B

A

1/4" Gap

12-1/2 lbs. max.

B

12-1/2 lbs. max.

3/8

3/4

Right

side

view

of

overlay
custom

panel

Route

for hinge

clearance

Front

7/8

3/8

Top

view

of

overlay
custom

panel

Route

for hinge

clearance

Front

A

B

Spacer Panel

Backer Panel

Overlay Panel

Overlay

Panel

1/4"

Backer

Panel

Door

.10 Inch

Spacer

Spacer Panel

Backer Panel

Overlay Panel

Maximum assembled panel weight is
25 pounds (12-1/2 pounds for each panel).

3/4" overlay panel dimensions (in inches)

A (width) B (height)

1/4" backer

23-3/16"

14-11/16"

0.10" spacer 22-1/2"

14-3/16"

3/4" overlay 23-5/8"

15-1/16"

Assemble overlay panels with glue and screws.

• Center spacer panel on the backer panel, left to right, and top

to bottom. Secure the panels with glue.

• Center the spacer/backer panel on the overlay panel. Secure

with glue and screws. Countersink all screws.

Note: Maintain 1/4" gap between the