Installation, Instructions, Warning – GE ZDP364NDPSS User Manual

Page 21: Convert natural gas to lp gas operation, Convert lp gas to natural gas operation

Advertising
background image

TOOLS YOU NEEDED FOR CONVERSION

2 CONVERT THE REGULATOR

Disconnect all electrical power at the main circuit

breaker or fuse box.

A. Remove the rear vent

trim (on ranges only) to

access the regulator.

The Rangetop regulator

is on the left bottom

corner.

B. Shut off the gas supply

by closing the manual shut-off valve in the unit or at the

wall.

C. Convert the pressure regulator:

• Unscrew the cap with plunger.

• Place your thumb against flat side of the plunger and

press down to snap the plunger out of the cap.

• Carefully look at the plunger to locate the NAT or LP

position.

• Turn the

plunger over

so that the

desired gas is

showing near

the bottom.

• Snap the

plunger back into the cap.

• Screw the cap back onto the regulator.

3 CHANGE BURNER ORIFICES

INSTALLATION

TIP:

First remove all

orifices and then start replacing them.

This will help to prevent the possibility

that some may not be replaced.

A. Remove the burner grates,

burner caps and burner heads.

B. Loosen the top burner

orifices using a 7 mm

nut driver. Use small

pliers to carefully lift out the orifices.

The main orifice is located low in

the center of the

burner, while the

simmer orifice is

located higher

beside the center

of the burner.

DOWN

FOR OFF

NAT

LP

LP

NAT

LP

NAT

NAT

LP

Gasket

Cap

Plunger

LP Position

NAT. Position

Pressure Regulator

Main

Orifice

Simmer

Orifice

WARNING:

This conversion must be

performed by a qualified installer or gas supplier in

accordance with the manufacturer’s instructions

and all codes and requirements of the authority

having jurisdiction. Failure to follow instructions

could result in serious injury or property damage.

The qualified agency performing this work assumes

responsibility for the conversion.

WARNING:

The rangetop, as shipped

from the factory, is set for use with its intended

gas. If you wish to use your rangetop with the

alternate gas, you must first replace the orifices

and convert the pressure regulator.

WARNING:

The following adjustments

must be made before turning on the burner.

Failure to do so could result in serious injury. Be

sure pressure regulator has been converted as

described in Step 2.

Safety Glasses

Small Flat-Head Screwdriver

(2 to 2.4 mm or 3/32” tip size,

60 mm long)

Crescent Wrench

1/4” and 7mm

Nutdrivers

Installation

Convert Natural Gas to LP Gas Operation

Instructions

Convert LP Gas to Natural Gas Operation

Small Pliers

1/2” Deepwell

Socket Wrench

Philips

Screwdriver

ORIFICE HOLDER

The range orifice holder

is located behind the front

access panel at the bottom

of the range.
The rangetop orifice holder

is located inside the range

insulation cover.
Additional orifices may be present. Use only the orifices

specified in the instructions for your range or rangetop.

Burner Cap

Burner

Head

Spark

Igniter

Burner Base

21

Griddle

Orifice

Grill

Orifice

Burner Orifices

1

Range Regulator

Advertising
This manual is related to the following products: