Ge monogram, Zifs360nxrh, Standard installation anti-tip bracket – GE ZIFS360NXRH User Manual

Page 2: Side view, Front view elec, Side view installed with anti-tip bracket, Front view of cutout with anti-tip bracket

Advertising
background image

STANDARD INSTALLATION

ANTI-TIP BRACKET

Product Specification Created 3/14

SIDE VIEW

W

24"

(61.0 )

2"

(5.1)

4"

(10.2)

7/16"

(1.1)

Trim overlap

3 1/2"

(8.9)

FRONT VIEW

ELEC.

35 1/2"

(90.2)

2 5/16"

(5.9)

*83 1/2" min

*84 1/2" max

(212.1-214.6)

*Trim will overlap

additional 7/16"

3 1/2"

(8.9)

75 1/2"

(191.8)

From floor

to bottom

of electrical

area

5 1/2"

(14.0)

9"

(22.9)

ZIFS360NXRH

SIDE VIEW INSTALLED

WITH ANTI-TIP BRACKET

5"

(12.7)

5"

(12.7)

WATER

3 1/2"

(9.0)

81 1/2"

(207.0)

Use two

additional hole

locations at end

of brackets

Wall

Studs

Screws

mounted

into vertical

wall studs

C

Make sure

holes selected

are centered

on the studs

L

FRONT VIEW OF CUTOUT

WITH ANTI-TIP BRACKET

SIDE VIEW

W

24"

(61.0 )

2"

(5.1)

4"

(10.2)

7/16"

(1.1)

Trim overlap

3 1/2"

(8.9)

FRONT VIEW

ELEC.

35 1/2"

(90.2)

2 5/16"

(5.9)

*83 1/2" min

*84 1/2" max

(212.1-214.6)

*Trim will overlap

additional 7/16"

3 1/2"

(8.9)

75 1/2"

(191.8)

From floor

to bottom

of electrical

area

5 1/2"

(14.0)

9"

(22.9)

ZIFS360NXRH

SIDE VIEW INSTALLED

WITH ANTI-TIP BRACKET

5"

(12.7)

5"

(12.7)

WATER

3 1/2"

(9.0)

81 1/2"

(207.0)

Use two

additional hole

locations at end

of brackets

Wall

Studs

Screws

mounted

into vertical

wall studs

C

Make sure

holes selected

are centered

on the studs

L

FRONT VIEW OF CUTOUT

WITH ANTI-TIP BRACKET

A

GE Monogram

®

36" Built-In All-Freezer

ZIFS360NXRH

A Mounting the junction

box in this location will

also allow for front

accessability through

access panel.

B Water supply area.

WARNING:

The freezer is top heavy

and must be secured to

prevent the possibility of

tipping forward. Failure to

do so may result in death

or serious injury.
The information below is

for cabinet design only.

When installing the anti-

tip system you must use

the product installation

instructions.

The information below

applies to all installation

constructions:
• A wall bracket, bolts and

toggles will be supplied

with the unit.

• The bolts will be used to

attach bracket to wall in

4 locations. Two of the

locations must penetrate

the center of the wall

studs.

• The toggles are used for

stability in drywall and

when metal studs are

encountered. Lag bolts

are used in wood studs.

• In installation opening,

measure 81 ½” from

floor and draw a

horizontal line.

• Locate and mark the wall

studs on horizontal line.

Verify at least two studs

have their centerlines

within the center 32.5”

of installation opening to

ensure 2 wall studs are

penetrated.

• The bracket will be

centered left to right in

opening with bottom of

bracket on the horizontal

line.

• When unit is placed in

opening, the bracket tabs

will align with openings

in back of the unit. The

unit will be secured to the

bracket using supplied

“L” bolts.

See Installation

Instructions for detailed

instructions.

NOTES

B

Advertising