Design guide, The installation space, Dimensions and clearances – GE ZICP360NXRH User Manual

Page 3

Advertising
background image

36" Frame to

Frame Width

*84" From

Floor to

Top Frame

35"

Case Width

*83-1/2"

at

Rear

25-3/8" Framed Models

25-3/4" Stainless Steel Models

Case Depth

Depth Including Handles:

26-7/8" Framed Models

27-3/4" Stainless Steel Models

28-11/16" Professional Style Models

THE INSTALLATION SPACE

Water And Electrical Locations

Electrical and water supply must be located as shown.

The cutout depth must be 24”

The refrigerator will project forward, slightly beyond

adjacent cabinetry, depending on your installation.

Allow minimum 1/8” air gap between case back & wall.

Cutout depth beneath a soffit:

When installed beneath a soffit, the soffit cannot exceed

the 24” installation depth shown. The top case trim

overlaps the bottom of the soffit.

Additional Specifications
‡$YROW+]RUDPSSRZHUVXSSO\LVUHTXLUHG

An individual properly grounded branch circuit or circuit

breaker is recommended. Install

a properly grounded 3-prong electrical receptacle

recessed into the back wall. Electrical must be located

on rear wall as shown.

Note: GFI (ground fault interrupter) is not recommended.

• Water line can enter the opening through the floor

or back wall. Route GE SmartConnect

kit or 1/4” O.D.

copper tubing between the cold water line and the

water connection location. The tubing should be

long enough to extend to the front of the refrigerator.

Installation of an easily accessible shut-off valve in the

water line is required.

DIMENSIONS AND CLEARANCES

* Shipping height. The

refrigerator can be

adjusted to fit into a

cutout that is 83-1/2

min. to 84-1/2

max.

height. Note that the top

case trim at the front is

1/2

higher and will

overlap upper cabinetry

or soffit. Use leveling

legs and wheels for a

maximum 1

height

adjustment.

Product Clearances

These refrigerators are equipped with a 2-position door

stop. The factory set 130° door swing can be adjusted to

90° if clearance to adjacent cabinets or walls is restricted.

3

6"

Wall View

Electrical

Area

84-1/2" max

83-1/2" min

Finished
Opening

75" From

Floor to Bottom

of Electrical Area

10"

24" Cutout Depth

35-1/2"

Finished Width

2-5/16"

5"

10"

10"

3-1/2"

3-1/2"

5"

3-1/2"

Water Supply

ZUG2, ZUGSS2 Unified Grille Panel Kit

• If you are installing two refrigerators, side by side,

the installation space must be 71-1/2” wide.

Note: Additional cutout width may be required when side

panels are used. Add side panel thickness to the finished

cutout to calculate rough-in width.

• The water and electrical locations for each product

must be located as shown.

‡$VHSDUDWH9+]RUDPSSRZHUVXSSO\LV

recommended for each product.

The finished
cutout width
must be
35-1/2”.

Allow 25” minimum clearance for a full 130° door

swing. Allow 15” for pan removal.
For a 90° door swing, allow 4” min. clearance to a wall,

for framed and stainless steel models. Allow 5” min.

clearance for professional style models. If the 90° door

stop position is used, pan access is maintained, but pan

removal is restricted.
See illustrations pages 4 and 5 to determine door swing

interaction with adjacent cabinets or countertops.

Design Guide