Configuration – AB Soft SigmaBlade N8406-026 User Manual

Page 56

Advertising
background image

(English)

34

Configuration

The Switch Module can be configured locally using the Serial Port or remotely using the Ethernet ports.

Connection via Serial Port


Use a serial cable (with a female DB-9 connector) to connect between a management console (such as a personal
computer) and the Serial Port. A communication software conformed to VT100 terminal emulation is required. Set
the parameters of communication software as shown in the table below.

Baud rate

9600

Data bits

8

Parity

None

Stop bits

1

Flow control

None

IMPORTANT:

A leased line cannot be connected to the Serial Port

directly.

NOTES:

The command line interface has 2 modes, AOS CLI and ISCLI. You
can set the Switch Module to use either CLI mode. By default, the
mode is AOS CLI.
Serial interface is not connected between this switch module and the
EM card. Therefore It is not available to connect from the Enclosure
Manager by using "CONNECT SWITCH" command on Blade
Enclosure(10U)

or

"connectswitch"

command

on

Blade

Enclosure(6U).