Cutout and product dimensions

Advance planning for above-the-cooktop ovens (240 or 120)
with Advantium Speedcook technology

Above-the-cooktop Advantium oven

Dimensions (in inches)

66" MIN.

Mounting

height

from floor

30" MIN.

width required

Exhaust outlet

connects to

3-1/4" X 10" duct

16-3/8 max

(Rear)

16 max

25-1/2

16 max

30 max

Minimum distance from

door hinge side to adjacent

wall should equal 1/2-inch.

13"

MAX.

12"

MIN.

(without

obstruction)

100˚

Door open

Cabinet Front

SIDE VIEW A-A

Cabinet Bottom Shelf

Filler Block

Self-Aligning Screw

Oven Top

Equivalent
to Depth of
Cabinet Recess

This distance can
NOT exceed 2” to
ensure proper
installation with
the provided
screws.

240V and 120V outlets

need to be spaced on

the side if the desire is

to setup with top

exhaust.

A

A

Note: Outside venting is optional. Vent (duct) can be

horizontal or vertical.

Dimensions and installation information

(in inches)

Hood exhaust duct

Outside ventilation requires a HOOD EXHAUST DUCT. Read the
following carefully.

Exhaust connection

The hood exhaust has been designed to mate with a standard
3-1/4" x 10" rectangular duct.
If a round duct is required, a rectangular-to-round transition
adaptor must be used. Do not use less than a 6"-diameter duct.

Rear exhaust

If a rear or horizontal exhaust is to be used, care should be taken
to align exhaust with the space between studs, or wall should be
prepared at the time it is constructed by leaving enough space
between the wall studs to accommodate exhaust.

Grille

Filter kit accessory

Filter kit

JX81D Recirculating

charcoal filter kit
To be used when the

Advantium oven cannot

be vented to the outside.

Maximum duct length

For satisfactory air movement, the total duct length of 3-1/4"
x 10" rectangular or 6" diameter round duct should not exceed
140 equivalent feet.

Elbows, transitions, wall and roof caps, etc.

Present additional resistance to airflow and are equivalent to a
section of straight duct which is longer than their actual physical
size. When calculating the total duct length, add the equiva-
lent length of all transitions and adaptors plus the length of all
straight duct sections. The chart below shows the approximate
feet of equivalent length of some typical ducts.

Duct

Equivalent

A. Rectangular-to-round

5 ft.

Transition adaptor

B. Wall cap

40 ft.

C. 90° round elbow

10 ft.

D. 45° round elbow

5 ft.

E.

90° rectangular elbow

25 ft.

F.

45° rectangular elbow

5 ft.

G.

Roof cap

24 ft.