TROUBLESHOOTING

Unit not warming up

• Not plugged in

• No electrical contact between

heating cylinder and base station

• Electrical contacts on heating

cylinder dirty or soiled with adhesive

• Check power cord

• Insert heating cylinder into

contact slot on base

• Clean electrical contacts on

heating cylinder

Problem

Cause

Solution

Adhesive has stopped

extruding

• Adhesive temperature too low

• Adhesive past shelf life

• Cured adhesive in cartridge tip

• Tightly seal cartridge and

re-heat in base unit

• Allow gun to cool, then install

a new cartridge

• Attempt to clear cartridge tip

Green indicator light

appears immediately after

changing cartridge

• Heating cylinder still hot from

previous use

• Ensure that “cold” cartridge is

heated for at least 12 minutes

BOND STRENGTH OF HiPURformer™ ADHESIVES

Strength Development

10 minutes

1 hour

24 hours

650 psi

1090 psi
1360 psi

600 psi

1130 psi
1480 psi

270 psi
600 psi
900 psi

Maple to Maple

WW30

WW60

MP75

Recommended Applications

E = Excellent adhesion G = Good adhesion NR = Not recommended

E

NR
NR
NR
NR
NR
NR
NR
NR
NR
NR
NR

E

NR
NR
NR
NR
NR
NR
NR
NR
NR
NR
NR

G

E
E
E
E
E
E
E
E
E
E
E

SUBSTRATE

WW30

WW60

MP75

118 psi
478 psi

1016 psi

MP300

G

E
E
E
E
E
E
E
E
E
E
E

MP300

Wood

Steel

Ceramics

Aluminum

ABS

Concrete/Brick

Vinyl

Glass/Marble

Melamine

PVC

Lexan

FRP

8