IP Ethernet Setup

The IP Ethernet Setup page permits the user to set the network address and network
access settings of the N-664. It also permits the user to designate up to four Pilot
servers for the N-664 to connect and sent configuration data and status updates to.

These three IP configuration strings must be provided in dotted-quad format and have a
maximum length of 15 characters. Note that changes to these settings take place
immediately, so if you change the unit’s IP address in this screen and then save the
settings you will have to enter the new IP address in the browser address bar to
reconnect to the unit. Changes to the network settings will also cause any active Pilot or
serial port network connections to disconnect. Those connections will then attempt to
reconnect with the new network settings.

The DNS is an optional field. If a valid DNS address is provided, it will be used to look
up the address of the mail server provided by the user.

Setting

Default Value

Range

IP Address

"192.168.0.246"

15 characters

Subnet Mask

"255.255.255.0"

15 characters

Default Gateway

"192.168.10.1"

15 characters

DNS

“0.0.0.0”

15 characters

MAC address

Unique for each unit

6 bytes hexadecimal

Setting

Default Value

Range

Pilot Server

1 - 4

Fixed

IP

"0.0.0.0"

15 characters

Port

8800

8000 - 32767