American Fibertek SMH10p-PoE User Manual

Page 123

Advertising
background image

114

a certain period (for details, see the IEEE 802.3af specification).

Capacitive Detection: If the port and capacitive detection are enabled, the

capacitances state reads in the voltage result from the constant current. This is then

subtracted from the pre-capacitance voltage to get a charge rate. If this charge rate

is within the window of the PD signatures, the device is considered to be discovered.

Start: Showing with a tick symbol, the system initializes and resets successfully.

 And then, click

Apply

to carry into effect.

Port: The index of PoE ports.

Enable State: Check it to enable the PoE function to the port.

Power Limit From: Check it to decide the power limit method.

Classification: When this check box is ticked, the system will limit the power

supply to the powered device in accordance with the related class.

Legacy: Check it to support the legacy power devices.

Priority: Pull down the selection menu item to choose the priority of power

supplying.

Port Limit (<15400) mW: User can key in the power limit value which is under 15.4

Watts.

Mode: Displays the operating mode of the port.

Current (mA): Displays the operating current of the port.

Voltage (V): Displays the operating voltage of the port.

Power (mW): Displays the power consumption of the port.

Determined Class: Displays the PD’s class.

 And then, click

Apply

to carry into effect.

Advertising