EOTech M914 (AN/PVS-14) Monocular Night Vision Device User Manual

Page 42

Advertising
background image

3-2

3.1 TROUBLESHOOTING – Continued

Table 3-1 Troubleshooting Procedures – Continued

Malfunction

Probable Cause

Corrective Action

3. Poor or

degraded image –

Continued.

c. Insufficient ambient

light.

c. Turn the Mode Switch to the IR

position to provide IR light source

per section 2.6, or momentarily

activate the IR LED Illuminator per

section 2.7.

d. Gain (contrast) not

adjusted to an appropriate

setting.

d. Adjust gain (contrast) to a

comfortable level per section 2.8.

e. Not focused for viewing

distance being observed

(minimum 9.8 inches).

e. Focus objective lens per

section 2.9.

f. Diopter setting not

adjusted correctly.

f. Adjust diopter setting per

section 2.10.

g. Sacrificial window

and/or demist shield

obscured by dirt, dust, or

grime.

g. Clean sacrificial window and/or

demist shield per section 3.2,

Optical Surfaces.

h. Sacrificial window

and/or demist shield

cracked or scratched.

h. Replace sacrificial window

and/or demist shield per section

2.5.

i. Objective lens and/or

eyepiece obscured by dirt,

dust or grime.

i. Remove sacrificial window

and/or demist shield. Clean

objective lens and/or eyepiece per

section 3.2, Optical Surfaces.

4. IR LED

Illuminator does

not appear to

operate or

provides

insufficient light.

a. IR LED Illuminator exit

port is dirty.

a. Clean IR LED Illuminator exit

port per section 3.2, Optical

Surfaces.

b. Viewed scene is outside

effective range of IR LED

Illuminator.

b. Limit use of IR LED Illuminator

to viewed scenes within a few

meters of the MNVD.



Advertising