POWER SUPPLY UNIT

WARNING:

electric shock, do not expose this unit

to reduce the risk of fire or

to rain or moisture.

CAUTION:

risk of electric shock.

do not open, high voltage.

refer all servicing to qualified personnel only

line voltage

switch

replace fuse

with same

type and rating

FUSE

ON

POWER

N9512423

5

4

3

2

1

1) POWER MULTI-PIN: 16 PIN AMP connector that screws into the matching socket on the back of the SLAM!. This

should be connected first. Rotate the whole connector until it mates with the socket, then just a turn or so on the outer

ring clockwise will complete the mating. Force will NOT be needed. The cable is 6 feet long and keeping the supply

6-12” away from other gear reduces the possibility of induced hum, though this supply won’t radiate much. The supply

may get reasonably warm, and this is an intentional trade-off to keep those magnetic fields minimal.
NOTE: The bulk of the power supply will not turn on (including the LED) unless this connector is inserted, because the

SLAM! remote controls the power for most of the Power Supply Unit.

2) IEC POWER SOCKET: Use the supplied IEC cable to connect the Power Supply Unit to wall current. This supplied

cable should be the proper type for your country.

3) POWER TOGGLE: “ON” is marked. Note that BOTH this toggle has to be in the ‘ON’ position and the SLAM!

front panel red ‘POWER’ button has to be pushed to turn on the SLAM!.

4) FUSE: The fuse protects you and the SLAM! in case of a catastrophe. Replace only with the same value and type.

Failure to do so voids the warrantee. For 117 volts AC mains this fuse is a 2 Amp standard 1/4” SLO-BLO MDL 2.

For 220 volts AC mains this fuse is a 1 Amp standard 1/4” SLO-BLO MDL 1. A blown fuse often looks ‘blackened’.

Several blown fuses indicates a problem needing repair. Both the Supply and SLAM! should be returned to the dealer or

Manley Labs for service if the correct value fuses continue to blow.

5) VOLTAGE CHANGE-OVER SWITCH. This should be set to the proper voltage for you country by the factory. The
switch is marked, and in general a good habit to verify this setting is correct before plugging any new gear in and turning

it on. The carton the SLAM! arrives in will also be marked for 117 or 220.

In case you were wondering about the handle, it is to mechanically protect the switches and fuse.

The 4 mounting screws allow the supply to be mounted in a rack or screwed down to something.