Chapter 4: sensors calibration, powerbeam – PowerTap Joule GPS User Guide User Manual

Page 22

Advertising
background image

Joule GPS User Guide page 22

CHAPTER 4: SENSORS

CALIBRATION, PowerBeam

Once you are paired with the PowerBeam Resistance Unit (RU) there are two options available to calibrate the device: Rolldown
calibration or Manual calibration. There is also an option to reset the most recent calibration back to the factory default values.

RU Sensor

Activate Sensor

Start Pairing

Name

RU1

Sensor ID

130

Delete Sensor

Calibrate

Back to Bike

9:34

A

On or Off. Typically, always On. The Auto Zero

function follows the same steps outlined for

Manual Zero but does it continually during the

ride, whenever the bike is coasting for 4 or

more seconds. If your bike is a fixed-geared

or track bicycle you may consider turning

Auto Zero off.

Calibrating or “zeroing the torque” refers to the

process of resetting the Torque Offset value of

the physical torque tube (where the internal

strain guages actually measure wheel torque).
1) Make sure the power meter is awake and

communicating with the Joule GPS. Make sure

the bike is still, with absolutely no pressure

on the pedals or tension in the chain.

2) Select Manual Zero on Power Sensor screen.

The Calbration screen will appear. Torque

RAW should be 0. The last saved Torque

Offset is displayed. The value is typically

500-524 in-lbs.

3) Select Manual Zero on Calibration Screen.

The Torque Offset value will update with the

torque tube calibration value, given the

current environmental conditions.

RU Calibration

Roll Down
Manual
Reset to Default

Back to RU Sensor

9:34

A

RU Roll Down

Back to RU Calibration

Pedal to

18-20 mph

9:34

A

mph

0.0

2:00

REMAIN

RU Manual

Back to RU Calibration

Use +/- to match

RU Watts to Power

9:34

A

RU WATTS

210

230

POWER

- +

Roll Down

Manual

Reset

The RU Roll Down calibration screen will flash the “Pedal to...” message until the wheel speed is in the specified range.

Once in range, the clock will begin to count down. Continue pedaling, keeping the speed in range for the entire

countdown. This will allow the tire temperature and pressure to stabilize. Once the timer reaches zero, stop pedaling

and allow the wheel to spin down.

Select Manual calibration when another power meter is present on the bike and paired to the Joule GPS.

Begin pedaling to see power values from both the RU and the power meter. Once the RU has been clamped against the

tire, it is advisable to spend about 2 minutes pedaling to warm up the tire to stabilize the pressures . The vertical bar on

the graphic will show the current calibration within the acceptable range. Use the [PLUS] and [MINUS] buttons to

increase/decrease the value until the RU Watts and Power Watts are matching. While calibrating, pedal at a consistent

power and be sure to give the RU time to adjust with each increase/decrease.

Reset to Default will reset all values to the factory default calibration.

OPTION DESCRIPTION

Advertising