background image

Pull side mounting

24”

min

24”

min

36”-48”

36”-48”

24”

min

24”

min

4

Power cable within the walls and

ceiling space is to be protected using

rigid conduit or flexible armored cable

(check local and national electrical codes).

If using rigid conduit 1/2” trade size should

be used and the conduit should protrude 1/2”

to 5/8” from the door jamb. If using flexible

armored cable, Arlington Industries

38AST clip fitting may be used.

5

F

If mounting on the pull side of the door: Take into

consideration proximity of sensor to door frame, length of

sensor wire and the vestibule area available.

5

Install power cable with minimum conductor size as required

by local codes, through the “F” hole for left hand door or “E”

hole for right hand door, in the door jamb. DO NOT CONNECT

TO LIVE CIRCUIT AT THIS TIME.

Push side mounting

4” min

36”-48”

Installation

Cut a hole for a single cut-in electrical box in the sensor

location.

If mounting on the push side of the door: Take into

consideration proximity of sensor to door frame, length of

sensor wire and the vestibule area available.

6

F

G

E

Insert sensor cable through the “G“ hole for left hand door

or “D” hole for right hand door, in the door jamb. If installing

multiple sensors, refer to Adding Additional Sensors section

Sensor must be installed in a location

which can be observed by the person

operating the sensor. Sensor must be in a

position such that user is prevented from

coming into contact with the door

while using sensor.

If using optional electric strike,

see Electric Srike Installation section,

page 10.

7

E

Feed sensor cable from hole in the door jamb to the cut-in box.

Pass cable through box and install box into wall (be sure the box is

properly grounded). If longer sensor cable length is needed, connect

the sensor extension cable (#1800383) to the provided sensor cable.

8

B

E

E

Connect sensor cable to the back of sensor plate.

2

9

1

C

J

Install the sensor plate to the cut-in box with two screws and

snap the sensor cover into place.

1

10

2

3

E

A

Position Auto Door unit near door jamb and pass all cables

through respective holes into unit.

6

Advertising