Technical specifications – Asian Phoenix Resources POWERPAL MHG-T2 User Manual

Page 15

Advertising
background image

a) Start the generator and adjust the spear valve to obtain 220-240 volts, 0 amps at the
panel. [Do not turn the circuit breaker on].
b) Adjust the potentiometer on the circuit board very slowly to the left. When you
detect a small decrease in voltage, stop. Turn on the circuit breaker and increase water
to increase power to the unit. Increase power until a load of 2kW is indicated (P =VI).
c) If adjusting the potentiometer does not correct the problem, then contact PowerPal.
The problem is probably with the potentiometer.


TECHNICAL SPECIFICATIONS

MHG-T2

1 Rated power output

2000W

2 Maximum allowable load

2200W

3 Intended voltage

220V~

4 Frequency at rated power output

50 Hz

5 Frequency at runaway speed

70 Hz

6 Runaway speed

1500rpm

7 Height

600mm

8 Weight

90kg

9 Turbine runner type

Turgo

10 Runner diameter

270mm

11 Number of buckets

20

12 Number of nozzles

1

13 Generator

3- phase

14 Generator insulation

Class B

15 Protection grade

IP54

16 Load controller circuit breaker

20A

17 Upper generator bearing size

Lower generator bearing size
Turbine bearing size

6206-2Z

SKF 7206B

SKF 1207

18 Seal size

38x58x10mm

19 Recommended cable

4mm2

20 Operating temperature

5 to 50

° C

21 Operating humidity

0 to 90%


Notes:

1,2.

Rated power output is the manufacturer’s specified output for the given head

and flow conditions. A higher output is possible if the head is greater or the flow is
faster than recommended. If the maximum allowable load is exceeded then permanent
damage to the stator may occur.

3.

Is approximately 220V when the ELC is used.


5,6.

Runaway speed is the speed of the rotor if no load is applied. This speed is

reduced under load.

18.

We recommend SKF brand or similar high quality bearings.


Also, the diagrams and much useful information on pages 7 and 16 are taken from
Micro-hydropower Sourcebook – A Practical Guide to Design and Implementation in
Developing Countries.
NRECA, 1986.

PowerPal™ T2 Turgo 15

Advertising