Introduction and front panel, Dump, Exit cough start – Symetrix RC-6000 Remote Control User Manual

Page 2: Quick start guide: rc-6000 remote control, Introduction, Mechanical data, Front panel, Rc-6000

Advertising
background image

2

QUICK START GUIDE: RC-6000 Remote Control

Introduction and Front Panel

6408 216th Street SW

|

Mountlake Terrace, WA 98043 USA

T

+1.425.778.7728

F

+1.425.778.7727

|

www.symetrix.co

Introduction

The AirTools RC-6000 is an accessory remote control
for the 6000 and 6100 Broadcast Audio Delays. The RC-
6000 Remote Control duplicates EXIT, START, COUGH and
DUMP buttons found on the front panel of

the AirTools 6000 and 6100. It also features LED indiction
of the delay’s current status including INACTIVE, ACTIVE,
HALF delay memory built and FULL delay memory built.

Mechanical Data

ITEM

DESCRIPTION

DETAILS

Space Required

WDH: 18.16 cm x 9.78 cm x 3.81 cm / 7.15 in x 3.85 in x 1.5 in.
Depth does not include connector allowance.

Allow at least 1 inch additional clearance for rear panel connec-
tions. Additional depth may be required depending upon your
specific wiring and connections.

Electrical

N/A

Power comes from the 6000 or 6100 via the included cable.

Ventilation

Maximum recommended ambient operating temperature is 30
C / 86 F.

Ventilation should not be impeded by covering the unit with items
such as newspapers, tablecloths, curtains, etc.

Weight

0.24 kg / 0.52 lbs.

FRONT PANEL

ITEM

DESCRIPTION

DETAILS

INACTIVE

Red LED

Indicates that the current delay is fully exited (exactly 0.0 seconds) and the status of the delay is
“DELAY REMOVED”.

ACTIVE

Red LED

Indicates that some amount of delay is currently built and the delay is currently in some mode of opera-
tion.

HALF

Red LED

Indicates that at least half of the currently set amount of delay has been achieved.

FULL

Red LED

Indicates that the full amount of the currently set amount of delay has been achieved.

EXIT

Momentary amber lighted switch

Mirrors the status and function of the EXIT button on the front of the delay. The button flashes to
indicate that the delay is “REDUCING DELAY TIME”.

START

Momentary green lighted switch

Mirrors the status and function of the START button on the front of the delay. The button flashes to
indicate that the delay is “ADDING DELAY TIME”.

COUGH

Momentary white lighted switch

Mirrors the status and function of the COUGH button on the front of the delay. The button lights while
the button is pressed to indicate that the delay is “WAITING FOR RELEASE”.

DUMP

Momentary red lighted switch

Mirrors the status and function of the DUMP button on the front of the delay. The button lights while the
button is pressed.

INACTIVE

ACTIVE

HALF

FULL

RC-6000

REMOTE

CONTROL

EXIT

COUGH

START

DUMP

Advertising