TROUBLESHOOTING
Problem
Cause
Solution
Setting coulter depth equally
Frame not set correctly
Ensure that in operation
the frame is level.
Blade not penetrating
Insufficient coulter spring
Tighten coulter spring
pressure.
locknut down 1” further.
Coulter incorrectly installed
Adjust height of coulter by
sliding
shank
down
at
the
clamp kit.
Spring not deflecting
Excessive spring pressure
Back off coulter spring
locknut.
Blade
not
rotating
Bearings
too
tight
See
maintenance
section
for proper bearing adjustment