Yetter 2000 Series AllSteer Plus Fertilizer Toolbar User Manual

Page 51

Advertising
background image

51

TROUBLESHOOTING



Problem

Cause

Solution


Setting coulter depth equally

Frame not set correctly

Ensure that in operation

the frame is level.


Blade not penetrating

Insufficient coulter spring

Tighten coulter spring

pressure.

locknut down 1” further.


Coulter incorrectly installed

Adjust height of coulter by

sliding

shank

down

at

the

clamp kit.


Spring not deflecting

Excessive spring pressure

Back off coulter spring

locknut.


Blade

not

rotating

Bearings

too

tight

See

maintenance

section

for proper bearing adjustment

Advertising